Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision Both sides next revision
en:zone_control_api [2018/03/15 14:34]
yjjung
en:zone_control_api [2018/03/15 14:51]
yjjung
Line 67: Line 67:
   * [[BS2_RemoveIntrusionAlarmZone]]:​ Removes selected Intrusion Alarm zones.   * [[BS2_RemoveIntrusionAlarmZone]]:​ Removes selected Intrusion Alarm zones.
   * [[BS2_RemoveAllIntrusionAlarmZone]]:​ Removes all Intrusion Alarm zones.   * [[BS2_RemoveAllIntrusionAlarmZone]]:​ Removes all Intrusion Alarm zones.
-  * [[BS2_SetIntrusionAlarmZoneArm]]:​ Configures Intrusion Alarm zones status Intrusion On/Off. +
-  * +
 \\ \\
 ---- ----
Line 76: Line 75:
   * [[BS2_GetInterlockZone]]:​ Gets selected Interlock zones.   * [[BS2_GetInterlockZone]]:​ Gets selected Interlock zones.
   * [[BS2_GetInterlockZoneStatus]]:​ Gets selected Interlock zone status.   * [[BS2_GetInterlockZoneStatus]]:​ Gets selected Interlock zone status.
-  * [[BS2_GetAllInterlockZoneStatus]]: ​모든 인터락 구역의 상태 정보를 가져옵니다+  * [[BS2_GetAllInterlockZoneStatus]]: ​Gets all Interlock zone's status information
-  * [[BS2_SetInterlockZone]]: ​인터락 구역을 설정합니다+  * [[BS2_SetInterlockZone]]: ​Sets Interlock Zones
-  * [[BS2_SetInterlockZoneAlarm]]: ​인터락 구역의 경보 상태를 갱신합니다+  * [[BS2_SetInterlockZoneAlarm]]: ​Updates the alarm status in the Interlock zone
-  * [[BS2_RemoveInterlockZone]]: ​주어진 인터락 구역을 제거합니다+  * [[BS2_RemoveInterlockZone]]: ​Removes the selected Interlock zone
-  * [[BS2_RemoveAllInterlockZone]]: ​모든 인터락 구역을 제거합니다.+  * [[BS2_RemoveAllInterlockZone]]: ​Removes all Interlock zones.
 \\ \\
 ---- ----
Line 86: Line 85:
 Not BioStar V2.x server, but specific device acts as Zone Master. Ethernet zone uses Ethernet TCP protocol between devices(Master <-> Members). Not BioStar V2.x server, but specific device acts as Zone Master. Ethernet zone uses Ethernet TCP protocol between devices(Master <-> Members).
  
-Curruently, it only supports ​correspoding ​features to exisiting ​1.x Entrance Limit, Fire Alarm Zone. +Currently, it only supports ​corresponding ​features to existing ​1.x Entrance Limit, Fire Alarm Zone. 
   * [[BS2_GetDeviceZone]]:​ Retrieves selected Ethernet zones..  ​   * [[BS2_GetDeviceZone]]:​ Retrieves selected Ethernet zones..  ​
   * [[BS2_GetAllDeviceZone]]:​ Retrieves all Ethernet zones.   * [[BS2_GetAllDeviceZone]]:​ Retrieves all Ethernet zones.
Line 468: Line 467:
  as **IntrusionAlarmZone.numDoors**. ​ \\ \\   as **IntrusionAlarmZone.numDoors**. ​ \\ \\ 
 7. //​groupIDs//​ \\  7. //​groupIDs//​ \\ 
-Access group list which belongs to Intrusion alarm zone. It needs to exist as much +Access group list which belongs to Intrusion alarm zone. It needs to exist as much as **IntrusionAlarmZone.numGroups**.  \\ \\  
- as **IntrusionAlarmZone.numGroups**. ​ \\ \\ +==== BS2InterlockZone==== 
 +<code cpp> 
 +typedef struct { 
 +    uint32_t zoneID; 
 +    char name[BS2_MAX_ZONE_NAME_LEN];​ 
 +    uint8_t disabled; 
 +    uint8_t numInputs;​ 
 +    uint8_t numOutputs;​ 
 +    uint8_t numDoors; 
 +    uint8_t reserved[8]; ​    
 +} BS2InterlockZone;​ 
 +</​code>​ 
 +1. //zoneID// \\  
 +Zone ID which needs to have a value higher than 1.\\ \\   
 +2. //name// \\  
 +Name of the zone that will be displayed on the BioStar application.. \\ \\ 
 +3. //​disabled//​ \\  
 +Decides whether the zone is disabled. ​ \\ \\  
 +4. //​numInputs//​ \\  
 +Number of intrusion detecting sensor inputs belonging to Interlock alarm zone. \\ \\  
 +5. //​numOutputs//​ \\  
 +Number of outputs belonging to Interlock alarm zone. \\ \\ 
 +6. //​numDoors//​ \\  
 +Number of doors belonging to Interlock alarm zone.  \\ \\  
 +7. //​reserved//​ \\  
 +Reserved space. ​ \\ \\ 
 + 
 +==== BS2InterlockZoneBlob==== 
 +<code cpp> 
 +typedef struct { 
 +    BS2InterlockZone InterlockZone;​ 
 +    BS2InterlockZoneInput* inputObjs;​ 
 +    BS2InterlockZoneOutput* outputObjs;​ 
 +    BS2_DOOR_ID* doorIDs; 
 +} BS2InterlockZoneBlob;​ 
 +</​code>​ 
 +1. //​InterlockZone//​ \\  
 +Structure that defines the basic Interlock alarm zone information. ​ \\ \\  
 +2. //​inputObjs//​ \\  
 +Input list which belongs to Interlock alarm zone. It needs to exist as much as **InterlockAlarmZone.numInputs**. ​ \\ \\ 
 +3. //​outputObjs//​ \\  
 +Output list which belongs to Interlock alarm zone. It needs to exist as much as **InterlockAlarmZone.numOutputs**. ​ \\ \\  
 +4. //doorIDs// \\  
 +Door list which belongs to Interlock alarm zone. It needs to exist as much as **InterlockAlarmZone.numDoors**.  \\ \\ 
  
 ==== BS2DeviceZoneEntranceLimitMaster==== ==== BS2DeviceZoneEntranceLimitMaster====