en:zone_control_api [2018/03/20 15:25] yjjung |
en:zone_control_api [2018/10/30 17:34] yjjung [BS2AntiPassbackZone] |
||
---|---|---|---|
Line 251: | Line 251: | ||
Reserved space. \\ \\ | Reserved space. \\ \\ | ||
9. //resetDuration// \\ | 9. //resetDuration// \\ | ||
- | The time interval for initializing the users status when a user violates the APB rule. When the value is set to 0, this means that it will not initialize the status, and will be initialized only through the BioStar application. \\ \\ | + | It means the time until the APB violation status is initialized(released), unit is second. At this time, the initialization time is calculated based on the time when the last authentication succeeded. If this value is set to 0, it means not to initialize but can be initialized with BS2_ClearAntiPassbackZoneStatus. \\ \\ |
10. //alarm// \\ | 10. //alarm// \\ | ||
An alarm that will be triggered when a user violates the user APB rule, which can be configured up to 5 alarms. \\ \\ | An alarm that will be triggered when a user violates the user APB rule, which can be configured up to 5 alarms. \\ \\ |