Differences
This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
en:configuration_api [2020/11/03 14:09] kkshin [BS2Action] |
en:configuration_api [2020/11/16 11:10] kkshin [BS2FaceConfigExt] |
||
---|---|---|---|
Line 2188: | Line 2188: | ||
uint8_t thermalFormat; | uint8_t thermalFormat; | ||
- | uint8_t reserved2[3]; | + | uint8_t reserved2; |
- | uint16_t thermalThreshold; | + | uint16_t thermalThresholdLow; |
+ | uint16_t thermalThresholdHigh; | ||
uint8_t maskDetectionLevel; | uint8_t maskDetectionLevel; | ||
uint8_t auditTemperature; | uint8_t auditTemperature; | ||
Line 2196: | Line 2197: | ||
uint8_t useRejectSound; | uint8_t useRejectSound; | ||
uint8_t useOverlapThermal; | uint8_t useOverlapThermal; | ||
- | uint8_t reserved4; | + | uint8_t useDynamicROI; |
uint8_t faceCheckOrder; | uint8_t faceCheckOrder; | ||
} BS2FaceConfigExt; | } BS2FaceConfigExt; | ||
Line 2238: | Line 2239: | ||
5. //reserved2// \\ | 5. //reserved2// \\ | ||
Reserved \\ \\ | Reserved \\ \\ | ||
- | 6. //thermalThreshold// \\ | + | 6. //thermalThresholdLow// \\ |
- | This is the standard value for determining high temperature and must be entered as a value multiplied by 100 of the temperature to be set. \\ | + | ''Supported version : FaceStation F2 V1.0.2, FaceStation 2 V1.5.0'' \\ |
+ | This is the range value for determining high temperature and must be entered as a value multiplied by 100 of the temperature to be set. \\ | ||
Also, you can only enter in degrees Celsius. \\ | Also, you can only enter in degrees Celsius. \\ | ||
- | This value is the basis for the denial of authentication, and the setting range is between 3000(30º) and 4500(45º). \\ \\ | + | This value is the basis for the denial of authentication, and the setting range is between 3000(30º) and 4500(45º). \\ |
- | + | The default value is 3200(32º), and if a value larger or smaller than the setting range is entered, the default value a set to 3200(32º). \\ | |
- | 7. //maskDetectionLevel// \\ | + | And you must set a value less than thermalThresholdHigh. \\ \\ |
+ | 7. //thermalThresholdHigh// \\ | ||
+ | This is the range value for determining high temperature and must be entered as a value multiplied by 100 of the temperature to be set. \\ | ||
+ | Also, you can only enter in degrees Celsius. \\ | ||
+ | This value is the basis for the denial of authentication, and the setting range is between 3000(30º) and 4500(45º). \\ | ||
+ | The default value is 3800(38º), and if a value larger or smaller than the setting range is entered, the default value a set to 3800(38º). \\ | ||
+ | And you must set a value greater than thermalThresholdLow. \\ \\ | ||
+ | 8. //maskDetectionLevel// \\ | ||
''FaceStation F2'' Sets the mask detection level. The detecting level is based on internal setting value. \\ | ''FaceStation F2'' Sets the mask detection level. The detecting level is based on internal setting value. \\ | ||
''FaceStation 2'' This setting is ignored. \\ | ''FaceStation 2'' This setting is ignored. \\ | ||
Line 2253: | Line 2262: | ||
|3 |Detection level (Very high) | | | |3 |Detection level (Very high) | | | ||
</WRAP> | </WRAP> | ||
- | 8. //auditTemperature// \\ | + | 9. //auditTemperature// \\ |
Decides whether the measured temperature is recorded in the log or not. \\ \\ | Decides whether the measured temperature is recorded in the log or not. \\ \\ | ||
- | 9. //useRejectSound// \\ | + | 10. //useRejectSound// \\ |
Decides whether it sounds when rejecting a user due to thermalThreshold or maskDetectionLevel. \\ \\ | Decides whether it sounds when rejecting a user due to thermalThreshold or maskDetectionLevel. \\ \\ | ||
- | 10. //useOverlapThermal// \\ | + | 11. //useOverlapThermal// \\ |
Displays a thermal image overlaid on the screen. \\ \\ | Displays a thermal image overlaid on the screen. \\ \\ | ||
- | 11. //reserved4// \\ | + | 12. //useDynamicROI// \\ |
- | Reserved \\ \\ | + | When set to true, when measuring temperature, the user's forehead is found and measured, not a fixed area. \\ \\ |
- | 12. //faceCheckOrder// \\ | + | 13. //faceCheckOrder// \\ |
It defines the sequence of thermal check and mask detection and authentication. \\ | It defines the sequence of thermal check and mask detection and authentication. \\ | ||
Because the user should touch the device in the case of ID combination authentication or PIN combination authentication,\\ | Because the user should touch the device in the case of ID combination authentication or PIN combination authentication,\\ | ||
Line 2293: | Line 2302: | ||
</code> | </code> | ||
1. //distance// \\ | 1. //distance// \\ | ||
- | The distance measured by the thermal imaging camera. The unit is cm, and the default is 70. \\ \\ | + | The distance measured by the thermal imaging camera. The unit is cm, and the default is 100. \\ \\ |
2. //emissionRate// \\ | 2. //emissionRate// \\ | ||
The rate of the subject reflecting heat. \\ | The rate of the subject reflecting heat. \\ |