en:configuration_api [2020/11/03 14:09]
kkshin [BS2Action]
en:configuration_api [2020/11/16 11:10]
kkshin [BS2FaceConfigExt]
Line 2188: Line 2188:
  
     uint8_t thermalFormat;​     uint8_t thermalFormat;​
-    uint8_t reserved2[3];+    uint8_t reserved2;
  
-    uint16_t ​thermalThreshold;+    uint16_t ​thermalThresholdLow;​ 
 +    uint16_t thermalThresholdHigh;
     uint8_t maskDetectionLevel;​     uint8_t maskDetectionLevel;​
     uint8_t auditTemperature;​     uint8_t auditTemperature;​
Line 2196: Line 2197:
     uint8_t useRejectSound;​     uint8_t useRejectSound;​
     uint8_t useOverlapThermal;​     uint8_t useOverlapThermal;​
-    uint8_t ​reserved4;+    uint8_t ​useDynamicROI;
     uint8_t faceCheckOrder;​     uint8_t faceCheckOrder;​
 } BS2FaceConfigExt;​ } BS2FaceConfigExt;​
Line 2238: Line 2239:
 5. //​reserved2//​ \\  5. //​reserved2//​ \\ 
 Reserved \\ \\ Reserved \\ \\
-6. //thermalThreshold// \\ +6. //thermalThresholdLow// \\ 
-This is the standard ​value for determining high temperature and must be entered as a value multiplied by 100 of the temperature to be set. \\+''​Supported version : FaceStation F2 V1.0.2, FaceStation 2 V1.5.0'' ​\\  
 +This is the range value for determining high temperature and must be entered as a value multiplied by 100 of the temperature to be set. \\
 Also, you can only enter in degrees Celsius. \\ Also, you can only enter in degrees Celsius. \\
-This value is the basis for the denial of authentication,​ and the setting range is between 3000(30º) and 4500(45º). \\ \\ +This value is the basis for the denial of authentication,​ and the setting range is between 3000(30º) and 4500(45º). \\ 
- +The default value is 3200(32º), and if a value larger or smaller than the setting range is entered, the default value a set to 3200(32º). ​\\ 
-7. //​maskDetectionLevel//​ \\+And you must set a value less than thermalThresholdHigh. \\ \\ 
 +7. //​thermalThresholdHigh//​ \\ 
 +This is the range value for determining high temperature and must be entered as a value multiplied by 100 of the temperature to be set. \\ 
 +Also, you can only enter in degrees Celsius. \\ 
 +This value is the basis for the denial of authentication,​ and the setting range is between 3000(30º) and 4500(45º). \\ 
 +The default value is 3800(38º), and if a value larger or smaller than the setting range is entered, the default value a set to 3800(38º). \\ 
 +And you must set a value greater than thermalThresholdLow. \\ \\ 
 +8. //​maskDetectionLevel//​ \\
 ''​FaceStation F2''​ Sets the mask detection level. The detecting level is based on internal setting value. \\ ''​FaceStation F2''​ Sets the mask detection level. The detecting level is based on internal setting value. \\
 ''​FaceStation 2''​ This setting is ignored. \\  ''​FaceStation 2''​ This setting is ignored. \\ 
Line 2253: Line 2262:
 |3  |Detection level (Very high)  |  | |3  |Detection level (Very high)  |  |
 </​WRAP>​ </​WRAP>​
-8. //​auditTemperature//​ \\ +9. //​auditTemperature//​ \\ 
 Decides whether the measured temperature is recorded in the log or not. \\ \\ Decides whether the measured temperature is recorded in the log or not. \\ \\
-9. //​useRejectSound//​ \\+10. //​useRejectSound//​ \\
 Decides whether it sounds when rejecting a user due to thermalThreshold or maskDetectionLevel. \\ \\ Decides whether it sounds when rejecting a user due to thermalThreshold or maskDetectionLevel. \\ \\
-10. //​useOverlapThermal//​ \\+11. //​useOverlapThermal//​ \\
 Displays a thermal image overlaid on the screen. \\ \\ Displays a thermal image overlaid on the screen. \\ \\
-11. //reserved4// \\  +12. //useDynamicROI// \\  
-Reserved ​\\ \\ +When set to true, when measuring temperature,​ the user's forehead is found and measured, not a fixed area. \\ \\ 
-12. //​faceCheckOrder//​ \\ +13. //​faceCheckOrder//​ \\ 
 It defines the sequence of thermal check and mask detection and authentication. \\ It defines the sequence of thermal check and mask detection and authentication. \\
 Because the user should touch the device in the case of ID combination authentication or PIN combination authentication,​\\ Because the user should touch the device in the case of ID combination authentication or PIN combination authentication,​\\
Line 2293: Line 2302:
 </​code>​ </​code>​
 1. //​distance//​ \\  1. //​distance//​ \\ 
-The distance measured by the thermal imaging camera. The unit is cm, and the default is 70. \\ \\+The distance measured by the thermal imaging camera. The unit is cm, and the default is 100. \\ \\
 2. //​emissionRate//​ \\ 2. //​emissionRate//​ \\
 The rate of the subject reflecting heat. \\ The rate of the subject reflecting heat. \\