Differences
This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
en:configuration_api [2022/09/14 16:07] mark |
en:configuration_api [2022/10/05 14:25] kateyu [BS2FaceConfig] |
||
---|---|---|---|
Line 1813: | Line 1813: | ||
[+ V2.7.1] ''FaceStation F2'' This indicates the width of the face image, and you can specify the minimum and maximum values. \\ | [+ V2.7.1] ''FaceStation F2'' This indicates the width of the face image, and you can specify the minimum and maximum values. \\ | ||
The default values of min and max are as follows. \\ | The default values of min and max are as follows. \\ | ||
- | <WRAP group 20%> | + | [+ 2.8.3] ''BioStation 3'' The settings are ignored. \\ |
- | ^ ^Default ^ | + | <WRAP group 30%> |
- | |min |66 | | + | ^ ^Default(min) ^Default(max) ^ |
- | |max |250 | | + | |FSF2 |66 |250 | |
+ | |BS3 |- |- | | ||
</WRAP> | </WRAP> | ||
Line 1822: | Line 1823: | ||
[+ V2.7.1] ''FaceStation F2'' Represents the face search range, and you can specify the x value (horizontal coordinate) of the range and the width from the x value point. \\ | [+ V2.7.1] ''FaceStation F2'' Represents the face search range, and you can specify the x value (horizontal coordinate) of the range and the width from the x value point. \\ | ||
The default values of x and width are as follows. \\ | The default values of x and width are as follows. \\ | ||
- | <WRAP group 20%> | + | [+ 2.8.3] ''BioStation 3'' The settings are ignored. \\ |
- | ^ ^Default ^ | + | <WRAP group 30%> |
- | |x |144 | | + | ^ ^Default(x) ^Default(width) ^ |
- | |width |432 | | + | |FSF2 |144 |432 | |
+ | |BS3 |- |- | | ||
</WRAP> | </WRAP> | ||
- | 14. //reserved2// \\ | + | |
+ | **14. //detectDistance//** \\ | ||
+ | [+ 2.8.3] ''BioStation 3'' This configures the minimum and maximum detection range for facial recognition. \\ | ||
+ | We no longer support faceWidth to pinpoint the face location using pixel units due to its complexity. \\ | ||
+ | Instead, we set the detection range of the subject(face). The unit is set to cm, and the value must be inputted as a multiple of 10. \\ | ||
+ | <WRAP group 80%> | ||
+ | ^ ^Min limit for min detection range ^Max limit for min detection range ^Min detection range(Default) ^Min limit for max detection range ^Max limit for max detection range ^Max sensing range(No limit) ^Max sensing range(Default) ^ | ||
+ | |BS3 |30 |100 |60 |40 |100 |255 |100 | | ||
+ | </WRAP> | ||
+ | |||
+ | **15. //wideSearch//** \\ | ||
+ | [+ 2.8.3] ''BioStation 3'' This can increase the detection range for facial recognition. \\ | ||
+ | We no longer support searchRange to set the x-coordinate and width due to its complexity. \\ | ||
+ | Instead, we set the face detection setting as default(FALSE), or a wide area(TRUE). \\ | ||
+ | The details of the settings and protocols for the detection of wide area is set within the device, which the user cannot change. \\ \\ | ||
+ | If this setting is set to TRUE, the camera detects subjects within a large range, and unintentionally detect and authenticate multiple subjects at once. Therefore, the default setting is at FALSE. \\ \\ | ||
+ | |||
+ | 16. //unused// \\ | ||
+ | Reserved space.\\ \\ | ||
+ | 17. //reserved// \\ | ||
Reserved space.\\ \\ | Reserved space.\\ \\ | ||
==== BS2Rs485ConfigEX ==== | ==== BS2Rs485ConfigEX ==== |