**12. //faceWidth//** \\ | **12. //faceWidth//** \\ | ||
[+ V2.7.1] ''FaceStation F2'' This indicates the width of the face image, and you can specify the minimum and maximum values. \\ | [+ V2.7.1] ''FaceStation F2'' This indicates the width of the face image, and you can specify the minimum and maximum values. \\ | ||
- | [+ 2.8.3] ''BioStation 3'' The settings are ignored. \\ | + | The default values of min and max are as follows. \\ |
<WRAP group 20%> | <WRAP group 20%> | ||
- | ^ ^Default(min) ^Default(max) ^ | + | ^ ^Default ^ |
- | |FSF2 |66 |250 | | + | |min |66 | |
- | |BS3 |- |- | | + | |max |250 | |
+ | </WRAP> | ||
**13. //searchRange//** \\ | **13. //searchRange//** \\ | ||
[+ V2.7.1] ''FaceStation F2'' Represents the face search range, and you can specify the x value (horizontal coordinate) of the range and the width from the x value point. \\ | [+ V2.7.1] ''FaceStation F2'' Represents the face search range, and you can specify the x value (horizontal coordinate) of the range and the width from the x value point. \\ | ||
The default values of x and width are as follows. \\ | The default values of x and width are as follows. \\ | ||
- | [+ 2.8.3] ''BioStation 3'' The settings are ignored. \\ | ||
<WRAP group 20%> | <WRAP group 20%> | ||
- | ^ ^Default(x) ^Default(width) ^ | + | ^ ^Default ^ |
- | |FSF2 |144 |432 | | + | |x |144 | |
- | |BS3 |- |- | | + | |width |432 | |
- | 14. //detectDistance// \\ | + | |
- | [+ 2.8.3] ''BioStation 3'' This configures the minimum and maximum detection range for facial recognition.. \\ | + | |
- | We no longer support faceWidth to pinpoint the face location using pixel units due to its complexity. \\ | + | |
- | Instead, we set the detection range of the subject(face). The unit is set to cm, and the value must be inputted as a multiple of 10. \\ | + | |
- | <WRAP group 80%> | + | |
- | ^ ^Min limit for min detection range ^Max limit for min detection range ^Min detection range(Default) ^Min limit for max detection range ^Max limit for max detection range ^Max sensing range(Infinite) ^Max sensing range(Default) ^ | + | |
- | |BS3 |30 |100 |60 |40 |100 |255 |100 | | + | |
</WRAP> | </WRAP> | ||
- | 15. //wideSearch// \\ | + | 14. //reserved2// \\ |
- | [+ 2.8.3] ''BioStation 3'' This can increase the detection range for facial recognition. \\ | + | |
- | We no longer support searchRange to set the x-coordinate and width due to its complexity. \\ | + | |
- | Instead, we set the face detection setting as default(false), or a wide area(true). \\ | + | |
- | The details of the settings and protocols for the detection of wide area is set within the device, which the user cannot change. \\ \\ | + | |
- | If this setting is set to TRUE, the camera detects subjects within a large range, and unintentionally detect and authenticate multiple subjects at once. \\ | + | |
- | Therefore, the default setting is at false. \\ \\ | + | |
- | 16. //unused// \\ | + | |
Reserved space.\\ \\ | Reserved space.\\ \\ | ||
- | 17. //reserved// \\ | ||
- | Reserved space.\\ \\ | ||
- | |||