Differences
This shows you the differences between two versions of the page.
| Next revision | Previous revision | ||
|
en:bln2_revision_note_150 [2022/08/24 15:05] mwkim created |
en:bln2_revision_note_150 [2024/08/16 11:13] (current) mashin |
||
|---|---|---|---|
| Line 5: | Line 5: | ||
| \\ | \\ | ||
| <callout type="primary" icon="true"> | <callout type="primary" icon="true"> | ||
| - | Devices with the new BLE chip or the SE processor cannot downgrade to a lower version after upgrading the firmware to v1.5.0. \\ | + | Devices with the new BLE chip and the SE processor cannot downgrade to a lower version after upgrading the firmware to v1.5.0 or higher. \\ |
| - | Devices with existing BLE chips or SE processor can be downgraded to a lower version. \\ | + | Devices with existing BLE chips and SE processor can be downgraded to a lower version. \\ |
| For more information, check the serial number of the device and contact the Suprema (supremainc.com). \\ | For more information, check the serial number of the device and contact the Suprema (supremainc.com). \\ | ||
| </callout> | </callout> | ||
| Line 19: | Line 19: | ||
| * The BLE chip parts of the hardware have been changed, and the firmware has been upgraded to be compatible with both the existing and new BLE chips. | * The BLE chip parts of the hardware have been changed, and the firmware has been upgraded to be compatible with both the existing and new BLE chips. | ||
| <text size="large">4.</text> Supports the dual SE processor. \\ | <text size="large">4.</text> Supports the dual SE processor. \\ | ||
| - | <text size="large">5.</text> Separated the log related to door unlock. \\ | + | <text size="large">5.</text> Separated the log related to the cause of the door unlock. \\ |
| - | * Door Unlocked (Exit Button) | + | * Door open request by exit button |
| - | * Door Unlocked (By Operator) | + | * Door open request by operator |
| <text size="large">6.</text> Added relay deactivation option for exit button input. \\ | <text size="large">6.</text> Added relay deactivation option for exit button input. \\ | ||
| * Added the option to set the door open request log to occur but the relay not to operate when the exit button is pressed. | * Added the option to set the door open request log to occur but the relay not to operate when the exit button is pressed. | ||
| Line 32: | Line 32: | ||
| <text size="large">3.</text> Device does not connect to a 3rd party controller (Software House iSTAR Edge G2) via OSDP (Affects version: v1.4.1). \\ | <text size="large">3.</text> Device does not connect to a 3rd party controller (Software House iSTAR Edge G2) via OSDP (Affects version: v1.4.1). \\ | ||
| <text size="large">4.</text> When changing the intelligent slave settings on the detailed page of the device on BioStar 2, the settings were not applied (Affects version: v1.4.2). \\ | <text size="large">4.</text> When changing the intelligent slave settings on the detailed page of the device on BioStar 2, the settings were not applied (Affects version: v1.4.2). \\ | ||
| - | <text size="large">5.</text> Migration malfunction occurs when the firmware is upgraded from v1.2.0 or earlier to v1.3.0 or later (Affects version: v1.3.0). \\ | + | <text size="large">5.</text> Migration malfunction occurs when the firmware is upgraded from v1.2.0 or earlier to v1.3.0 or higher (Affects version: v1.3.0). \\ |
| * Migration did not complete and the device boots to the main screen, some keys do not work or an abnormal screen is displayed. | * Migration did not complete and the device boots to the main screen, some keys do not work or an abnormal screen is displayed. | ||
| - | <text size="large">6.</text> When the device was communicating with a 3rd party system via OSDP, if the Input Status Request command was sent after the input port was grounded, the output was ’Inactive’ (Affects version: v1.4.1). \\ | + | <text size="large">6.</text> When communicating with a 3rd party control panel via OSDP, the device incorrectly responds as 'Inactive' when receiving the Input Status Request command while the input port is grounded (Affects version: v1.4.1). \\ |
| - | <text size="large">7.</text> If sending the Output Status Report Request command when the device was communicating with a 3rd party system via OSDP, the relay works, but the Output Status Report does not output (Affects version: v1.4.1). \\ | + | <text size="large">7.</text> When communicating with a 3rd party control panel via OSDP, the device does not respond to the Output Status Report command while the relay reacts to it (Affects version: v1.4.1). \\ |
| - | <text size="large">8.</text> When the device was communicating with a 3rd party system via OSDP, if the Output Status Request command was sent while relay status was ON, the output was ’Inactive’ (Affects version: v1.4.1). \\ | + | <text size="large">8.</text> When communicating with a 3rd party control panel via OSDP, the device incorrectly responds as 'Inactive' when receiving the Output Status Request command while the relay status is 'On' (Affects version: v1.4.1). \\ |
| - | <text size="large">9.</text> Device does not recognize some HID iCLASS Seos cards (Affects version: v1.0.0). \\ | + | <text size="large">9.</text> Device does not recognize certain HID iCLASS Seos cards (Affects version: v1.0.0). \\ |