Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
Next revision Both sides next revision
en:how_to_configure_secure_communication_between_device_and_server_tls_ssl [2017/03/15 15:11]
127.0.0.1 external edit
en:how_to_configure_secure_communication_between_device_and_server_tls_ssl [2019/09/17 21:32]
kate [Configuration]
Line 14: Line 14:
 When the device connects to the server, it will exchange an encryption key (session key) using the digital certificate to provide server identity verification. \\ When the device connects to the server, it will exchange an encryption key (session key) using the digital certificate to provide server identity verification. \\
 {{:​en:​2x_sc_secure_communication_ssl_tls_02.png?​nolink&​500|}} \\ {{:​en:​2x_sc_secure_communication_ssl_tls_02.png?​nolink&​500|}} \\
 +
 +<callout type="​info"​ icon="​true">​
 +BioStar 2 supports TLS version 1.1 and 1.2. 
 +For more generic security information refer to the [[http://​support.supremainc.com/​solution/​articles/​24000013983--biostar-2-personal-information-and-communication-security-encryption-tls|FAQ article ]]
 +</​callout>​
 +
  
 ===== Configuration ===== ===== Configuration =====
Line 19: Line 25:
 Access to the devices can be limited while this feature is turned on.  \\ Access to the devices can be limited while this feature is turned on.  \\
 It will take several minutes for the devices to reconnect to the server. \\ It will take several minutes for the devices to reconnect to the server. \\
 +**Port 51213 should be enabled if TLS/SSL: is used.** \\
 </​callout>​ </​callout>​
  
Line 27: Line 34:
 - BioStation A2 FW 1.3.0 or later  \\ - BioStation A2 FW 1.3.0 or later  \\
 - BioStation 2 FW 1.4.0 or later \\ - BioStation 2 FW 1.4.0 or later \\
 +- FaceStation 2 FW 1.1.0 or later (to be released in 2018) \\
 +- CoreStation FW 1.0.0 or later \\
 +- P2 FW 1.0.0 or later \\ 
 </​callout>​ </​callout>​
  
Line 43: Line 53:
 **Caution** \\ **Caution** \\
 Do not turn off the secure communication option if the device is physically disconnected from the network while using the secure communication feature. \\ Do not turn off the secure communication option if the device is physically disconnected from the network while using the secure communication feature. \\
-If the feature is turned off, the certificate of BioStar 2 will be deleted and the device will not be able to the server ​connect ​again. \\+If the feature is turned off, the certificate of BioStar 2 will be deleted and the device will not be able to connect ​to the server again. \\
 To connect the device to the server again, the certificate saved in the device must be deleted or the device must be reset to factory default. \\ To connect the device to the server again, the certificate saved in the device must be deleted or the device must be reset to factory default. \\
-For more details regarding ​factory default, refer to the manual of the device.+For devices without LCD such as W2 or P2 you can factory default the device with the reset buttons as shown in the device ​manual\\ 
 +Refer to the FAQ article: [[http://​support.supremainc.com/​solution/​articles/​24000014900--both-biostar-network-and-factory-default-w2|Factory Default W2 / P2]]
 </​callout>​ </​callout>​