Differences
This shows you the differences between two versions of the page.
en:bew2_revision_note_163 [2021/05/28 10:45] chloe created |
en:bew2_revision_note_163 [2021/06/01 13:46] (current) chloe |
||
---|---|---|---|
Line 7: | Line 7: | ||
<text size="large">1.</text> Upgraded to the 1.1.1i version of OpenSSL. \\ | <text size="large">1.</text> Upgraded to the 1.1.1i version of OpenSSL. \\ | ||
- | |||
<text size="large">2.</text> Intelligent Slave Support \\ | <text size="large">2.</text> Intelligent Slave Support \\ | ||
* Intelligent Slave: A function that enables 1:1 or 1:N matching directly from the Suprema device and transmits the authentication result as OSDP card data to the third-party controller. | * Intelligent Slave: A function that enables 1:1 or 1:N matching directly from the Suprema device and transmits the authentication result as OSDP card data to the third-party controller. | ||
- | |||
<text size="large">3.</text> Improved that LFD Driver IC damage does not affect fingerprint recognition performance. \\ | <text size="large">3.</text> Improved that LFD Driver IC damage does not affect fingerprint recognition performance. \\ | ||
<text size="large">4.</text> The transmission power level for Bluetooth Low Energy (BLE) has been adjusted. \\ | <text size="large">4.</text> The transmission power level for Bluetooth Low Energy (BLE) has been adjusted. \\ | ||
Line 17: | Line 15: | ||
==== Bug Fixes ==== | ==== Bug Fixes ==== | ||
<text size="large">1.</text> Card data were output with the wrong BitCount when the device was connected to a 3rd-party system via OSDP. (Affects version: v1.0.0) \\ | <text size="large">1.</text> Card data were output with the wrong BitCount when the device was connected to a 3rd-party system via OSDP. (Affects version: v1.0.0) \\ | ||
- | |||
- | |||
<text size="large">2.</text> When calling the BS2_ResetConfigExceptNetInfo API from the BioStar 2 Device SDK, a ‘Timeout’ error occurred. (Affects version: v1.0.0) \\ | <text size="large">2.</text> When calling the BS2_ResetConfigExceptNetInfo API from the BioStar 2 Device SDK, a ‘Timeout’ error occurred. (Affects version: v1.0.0) \\ | ||
- | |||
<text size="large">3.</text> It was not able to communicate with a 3rd-party controller via OSDP with the default key before network initialization. (only for devices released with the firmware version 1.5.0 or later) (Affects version: v1.0.0) \\ | <text size="large">3.</text> It was not able to communicate with a 3rd-party controller via OSDP with the default key before network initialization. (only for devices released with the firmware version 1.5.0 or later) (Affects version: v1.0.0) \\ | ||
- | |||
<text size="large">4.</text> It was able to communicate using default keys after changing the key settings when the device was connected to a 3rd-party device via OSDP. (Affects version: v1.0.0) \\ | <text size="large">4.</text> It was able to communicate using default keys after changing the key settings when the device was connected to a 3rd-party device via OSDP. (Affects version: v1.0.0) \\ | ||
- | |||
<text size="large">5.</text> After initializing the slave device’s settings, it was not able to connect it to a 3rd-party controller. (Affects version: v1.6.0) \\ | <text size="large">5.</text> After initializing the slave device’s settings, it was not able to connect it to a 3rd-party controller. (Affects version: v1.6.0) \\ | ||