Differences
This shows you the differences between two versions of the page.
| Both sides previous revision Previous revision | |||
|
en:how_to_use_timed_anti_passback [2024/12/18 11:42] jake |
en:how_to_use_timed_anti_passback [2024/12/18 12:58] (current) jake |
||
|---|---|---|---|
| Line 48: | Line 48: | ||
| 2. Supports the Alarm Function \\ | 2. Supports the Alarm Function \\ | ||
| - | * **If using BioStar 2 v2.9.7 or lower version:** \\ The alarm function Does Not support "Timed Anti Passback" yet but only supports "Anti PassBack" in the configured door. | + | * **If using BioStar 2 v2.9.7 or lower version:** \\ The alarm function Does Not support "Timed Anti Passback" yet but only supports "Anti PassBack" in the configured door. \\ {{:en:8t.png?700|}} |
| + | * **If using BioStar 2 v2.9.8 or higher version:** \\ The alarm function supports both "Timed Anti Passback" and "Anti PassBack" for the configured door. \\ {{:en:9t.png?700|}} | ||
| + | 3. If the door is set up with a wireless door lock, "Timed Anti Passback" CAN NOT be used. \\ | ||
| + | |||
| + | 4. "Timed Anti PassBack" and "Use sensor when Entry Confirmed APB" enabled features cannot be used simultaneously. \\ {{:en:10t.png?700|}} | ||
| + | |||
| + | ===== Execution Procedure ===== | ||
| + | === Step 1. Click DOOR in BioStar 2 === | ||
| + | {{:en:11t.png?300|}} | ||
| + | | ||
| + | === Step 2. Click ADD DOOR === | ||
| + | {{:en:12t.png?300|}} | ||
| + | |||
| + | === Step 3. Set the configuration you want to use === | ||
| + | {{:en:13t.png?300|}} | ||
| + | |||
| + | <callout type="primary" icon="true"> | ||
| + | You can select the "Entry device only" or the "Entry device + Exit device" depending on your environment. \\ | ||
| + | {{:en:14t.png?400|}} | ||
| + | </callout> | ||
| + | |||
| + | === Step 4. === | ||
| + | * **If using BioStar 2 v2.9.7 or lower version** \\ : Enable "Timed APB" and set the applicable "Reset Time" in Timed Anti PassBack. After completing it, click Apply. \\ {{:en:15t.png?400|}} \\ After completing it, if you want set "Bypass Group", select some specific access groups in "Bypass Group" \\ {{:en:16t.png?400|}} \\ And then, if you want to set the Alarm for "Timed Anti PassBack", configure the alarm by clicking the Add button. If completing all settings, click Apply. \\ {{:en:17t.png?400|}} | ||
| + | |||
| + | === Step 5. After completing Step 4, you can go through the set door (if using BioStar 2 v2.9.7 or lower version) or the set device (if using BioStar 2 v2.9.8 or higher version) only after the set-"Reset Time" has passed. === | ||
| + | |||
| + | For example, if you set the "Reset Time" to 1 minute, you can go through the set door 1 minute only after you have passed. \\ | ||
| + | |||
| + | <callout type="primary" icon="true"> | ||
| + | If you want to disable the set "Timed Anti PassBack", please follow the below guide per the BioStar 2 version used. \\ **1) If using BioStar 2 v2.9.7 or lower version,** \\ : Disable "Timed APB" and click Apply. \\ {{:en:18t.png?400|}} \\ **2) If using BioStar 2 v2.9.8 or higher version,** \\ : Select "No device" and click Apply. \\ {{:en:19t.png?400|}} | ||
| + | </callout> | ||