2024-07-10
1. XPass D2 new BLE (Bluetooth Low Energy) chip firmware (Build No. 1.7.0_220921) support.
2. Improved synchronization to complete if user enrollment fails when synchronizing multiple users to the device in BioStar 2.
3. Improved smartcard output byte order setting.
4. Improved to not recognize SEOS configuration cards as CSN for 1 minute after device booting.
5. Improved to get user update succeeded event log using the GetLogWithFilter function in the SDK.
6. Improved to ensure that values set with osdp_comset are correctly applied on the device connected as a slave.
1. Device does not recognize certain HID iCLASS Seos cards. (Affects version: v1.0.0)
2. Restart log is not logged in the device’s Event Log when the master device is restarted. (Affects version: v1.6.0)
3. Device does not recognize certain MIFARE Classic cards. (Affects version: v1.0.0)
4. Authentication fails when authenticating with a DESFire AoC while the device is connected as a slave. (Affects version: v1.0.0)
5. The user ID stored as a 32-character string is truncated to only 31 characters in a specific event log. (Affects version: v1.0.0)
6. When a user with a 32-character user ID authenticates to the device while the device is not connected to the server, the authentication event log is not updated in BioStar 2 even after the device is reconnected to the server. (Affects version: v1.0.0)
7. When the bit interval is set for the Facility Code and ID Field of the Wiegand card format and the card is scanned during add user, the Facility Code is displayed as an incorrect value. (Affects version: v1.4.1)