Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
en:how_to_configure_an_alarm_zone [2017/10/11 14:41]
ethan created
en:how_to_configure_an_alarm_zone [2021/12/29 15:36] (current)
peterk
Line 1: Line 1:
 {{tag>"​System Configuration"​ "​BioStar 2" "Alarm Zone"​}} {{tag>"​System Configuration"​ "​BioStar 2" "Alarm Zone"​}}
  
-Alarm zone has introduced with BioStar 2.5. It is used to detect any attempts of intrusion during an armed status. \\+====== How to Configure an Alarm Zone ====== 
 + 
 +Alarm zone has been introduced with BioStar 2.5. It is used to detect any attempts of intrusion during an armed period. \\
  
 You can trigger the device to make sounds or send a relay on the event of an intrusion.\\ You can trigger the device to make sounds or send a relay on the event of an intrusion.\\
Line 13: Line 15:
 Note that only local zone with RS485 connection is supported right now. Global zone, which would be server matching of the zone information is currently unavailable. ​ \\ Note that only local zone with RS485 connection is supported right now. Global zone, which would be server matching of the zone information is currently unavailable. ​ \\
  
-The alarm zone can detect intrusion based on the configured input and the sensor of the door is also used for detecting intrusion. ​ \\+The alarm zone can detect intrusion based on the configured input. Sensors on the door are also used for detecting intrusion. ​ \\
  
 You can configure various output and sound for the Alarm status. In the Trigger & Action menu you can configure the zone settings so that an email is sent to the administrator on a specific event. ​ \\ You can configure various output and sound for the Alarm status. In the Trigger & Action menu you can configure the zone settings so that an email is sent to the administrator on a specific event. ​ \\
  
-During ​an armed status, users will be unable to enter and an attempt to authenticate will be logged as intrusion alarm access denied. For further information on the types of event logs, please refer to the knowledge base configuration guide regarding Alarm Zone.  \\+While it has an armed status, users will be unable to enter and an attempt to authenticate will be logged as intrusion alarm access denied. For further information on the types of event logs, please refer to the knowledge base configuration guide regarding Alarm Zone.  \\
  
  
-====== How to Configure an Alarm Zone ======+===== Configuration ​=====
  
 1. Add a device to BioStar 2. \\ 1. Add a device to BioStar 2. \\
Line 26: Line 28:
 2. Add the device to a door.  \\ 2. Add the device to a door.  \\
  
-Refer to door configuration link http://​kb.supremainc.com/​knowledge/​doku.php?​id=en:​how_to_make_doors+Refer to door configuration link [[http://​kb.supremainc.com/​knowledge/​doku.php?​id=en:​how_to_make_doors|How to add and configure doors]]
 \\ \\
  
Line 90: Line 92:
 {{:​en:​2x_sysconfig_alarm_zone_006.png?​800|}}\\ {{:​en:​2x_sysconfig_alarm_zone_006.png?​800|}}\\
  
 +<callout type="​info"​ icon="​true">​ 
 +If you want to turn off the **Alert Sound** after an Alarm event you have to **Clear Alarm** in the **Monitoring** > **Device Status** menu  
 +</​callout>​
 ====== Video Demonstration ====== ====== Video Demonstration ======
  
Line 98: Line 102:
  
 <callout type="​warning"​ icon="​true">​ <callout type="​warning"​ icon="​true">​
-You can clear the alarm in the **Zone Status** tab of the **Monitoring** page but you cannot disable the arm status within BioStar 2’s menu. </​callout>​+You can clear the alarm in the **Zone Status** tab of the **Monitoring** page butyou cannot disable the arm status within BioStar 2’s menu. </​callout>​
  
-====== Supported Devices ​======+===== Supported Devices =====
  
-Below are the devices ​that support alarm zone in BioStar 2.5:  \\+   * ** The devices ​below support alarm zone from BioStar 2.5: ** \\
  
--      BioStation 2 FW 1.5.0 \\ +{{:​en:​alarmzone1.png?600|}}\\
--      BioStation A2 FW 1.4.0 \\ +
--      CoreStation FW 1.0.0 \\ +
--      P2 FW 1.0.0 \\ +
--      R2 FW 1.0.0 \\+
  
-The devices below will support alarm zone in the future (end of 2017):+   * ** The devices below support alarm zone from BioStar 2.6.0**
  
--      BioStation L2 FW 1.3.0 +{{:​en:​alarmzone2.png?​600|}}\\
--      W2 FW 1.2.0 +
--      FaceStation 2 FW 1.1.0+
  
 Other entry devices do not support this zone. \\ Other entry devices do not support this zone. \\
 +