 {{tag>"​System Configuration"​ "​BioStar 2" Door}} {{tag>"​System Configuration"​ "​BioStar 2" Door}}
  
-===== How to make doors =====+===== How to add and configure ​doors =====
 ---- ----
 <callout type="​tip"​ icon="​true">​ <callout type="​tip"​ icon="​true">​
-With the door setting, ​the basic relay and door level alarm configurations are supported. The minimum door element is '​Relay'​.  +With the door setting, basic relay and door level alarm configurations are possible. The minimum door element is '​Relay'​.  
-As long as you set a relay, it can be configured as a door. This is useful for the case of having to make a door open or close at the time of the designated event, such as fire alarm, or emergency lock down. +As long as you set a relay, it can be configured as a door. This is useful for the case of having to make a door open or close at the time of designated event, such as fire alarm, or emergency lock down. 
 </​callout>​ </​callout>​
    
Line 24: Line 24:
   * Entry device refers to the device located outside for entry input.   * Entry device refers to the device located outside for entry input.
   * Exit device refers to the device located inside for exit input.  ​   * Exit device refers to the device located inside for exit input.  ​
-  * Therefore, it's necessary to set to use a door relay from exit device or a door IO device, such as Secure IO 2 and DM-20, to avoid security risk of exposing a relay wiring to the outside. ​+  * Therefore, it's necessary to set to use a door relay from an exit device or a door IO device, such as Secure IO 2 and DM-20, to avoid security risk of exposing a relay wiring to the outside. ​ 
 +  * **Door Sensor** can be used to monitor the door status. BioStar 2 System Administrator or users can know the physical door status via the sensor detection whether the door is opened or closed. Moreover, it can be used to generate an alarm for any unexpected door status. 
 +  * It is highly recommended to set the door sensor in BioStar 2 Door Configuration and wire the door status sensor to the door. If the **Door opened** log is detected without the occurrence of the **Door unlocked** log, BioStar 2 software or BioStar 2 Products generate a **Forced door opened** log and also can generate an additional **Forced door open alarmed** to notify the user. 
  
 +</​callout>​
 +
 +<callout type="​primary"​ icon="​true">​
 +Once a device is added to a door, the device authentication mode changes to **No Access**. \\
 +In order to allow user access, configure **[[en:​how_to_make_access_groups|Access Groups]]**. ​
 </​callout>​ </​callout>​
  
 {{:​en:​28.png?​nolink&​800|}} {{:​en:​28.png?​nolink&​800|}}
        
-3) If the door sensor is applied, Held Open and Forced Open alarm can be set to use. Click '​+Add'​ button on the leftand set to use '​Output'​ and select the device to make an '​Output'​and the relay to send out output signal. But if you want to make an alert only, you need to set the device which is not used for the door relay or other important output to the '​Device'​ and its relay to '​Output'​. This is because it can be mixed and create an unplanned relay output. ​  ​+3) If the door sensor is applied, Held Open and Forced Open alarm can be set to use. Click '​+Add'​ button on the left and set to use '​Output'​ and select the device to make an '​Output'​ and the relay to send out an output signal. But if you want to make an alert only, you need to set the device which is not used for the door relay or other important output to the '​Device'​ and its relay to '​Output'​. This is because it can be mixed and create an unplanned relay output. ​ 
  
 {{:​en:​29.png?​nolink&​800|}} {{:​en:​29.png?​nolink&​800|}}
- 
 \\ \\
 {{:​en:​35.png?​nolink&​800|}} {{:​en:​35.png?​nolink&​800|}}
  
  
 +
 +i.e. Held Open Alarm Configuration for the door 
 +This configuration will help to generate the Held door open alarmed log once the door opened log is kept more than Held Open Time. 
 \\ \\
 +{{:​en:​heldopen_alarm_01.png?​1000|}}
  
-{{:en:32.png?​nolink&​800|}}+ 
 +i.e. Forced Open Alarm Configuration for the door 
 +This configuration will help to generate the Forced door open alarmed log once the door opened log is detected without door unlocked log which is normally generated by user authentication,​ pressing a configured exit button, or clicking Open button on BioStar 2.
 \\ \\
 +{{:​en:​forcedopen_alarm_02.png?​1000|}}
 +
  
 4) Set the held open time from 1 sec to 15 min range. If the door is remained open longer than this held open time setting, the alert event occurs to call attention to the situation. ​ 4) Set the held open time from 1 sec to 15 min range. If the door is remained open longer than this held open time setting, the alert event occurs to call attention to the situation. ​
  