Line 14: Line 14:
 \\ \\
 \\ \\
-===== 1. This function is supported only when the Suprema device is directly connected to BioStar 2 via Ethernet. ​=====+=== 1. This function is supported only when the Suprema device is directly connected to BioStar 2 via Ethernet. ===
   * RS-485 Mode: Default, Master, Slave (but connected via Ethernet)   * RS-485 Mode: Default, Master, Slave (but connected via Ethernet)
   * You CANNOT set when the Suprema device is connected as a slave device of the Suprema device.   * You CANNOT set when the Suprema device is connected as a slave device of the Suprema device.
  
-===== 2. Options are only applicable for Wiegand output and OSDP output. ​=====+=== 2. Options are only applicable for Wiegand output and OSDP output. ===
   * Write Smart Card and Read Card are not affected.   * Write Smart Card and Read Card are not affected.
  
-===== 3. Operation according to RS-485 Mode =====+=== 3. Operation according to RS-485 Mode ===
   * Default, Master, Slave (but connected via Ethernet): Operates according to the device'​s 'Smart Card Output Byte Order' setting.   * Default, Master, Slave (but connected via Ethernet): Operates according to the device'​s 'Smart Card Output Byte Order' setting.
   * When connected to the Slave device of the Suprema device: The Slave transmits the Card ID to the Master device and operates according to the 'Smart Card Output Byte Order' setting in the Master device.   * When connected to the Slave device of the Suprema device: The Slave transmits the Card ID to the Master device and operates according to the 'Smart Card Output Byte Order' setting in the Master device.
  
-===== 4. Operation according to Wiegand Output ​=====+=== 4. Operation according to Wiegand Output ===
   * When Output info is Card ID: Operates according to the setting.   * When Output info is Card ID: Operates according to the setting.
   * When Output info is User ID: Not influenced.   * When Output info is User ID: Not influenced.
  
-===== 5. Actions according to the card type =====+=== 5. Actions according to the card type ===
   * MIFARE, DESFire: Operates according to the 'Smart Card Output Byte Order' setting.   * MIFARE, DESFire: Operates according to the 'Smart Card Output Byte Order' setting.
   * iClass: Not influenced. Output PAC data as it is.   * iClass: Not influenced. Output PAC data as it is.
   * BioStar 2 QR: Not influenced.   * BioStar 2 QR: Not influenced.