Line 375: Line 375:
     uint8_t shortcutHome[BS2_MAX_SHORTCUT_HOME];​     uint8_t shortcutHome[BS2_MAX_SHORTCUT_HOME];​
     uint8_t tnaIcon[16];​     uint8_t tnaIcon[16];​
-    uint8_t reserved1[32];+    ​uint8_t useScreenSaver;​ 
 +    ​uint8_t reserved1[31];
 } BS2DisplayConfig;​ } BS2DisplayConfig;​
 </​code>​ </​code>​
Line 415: Line 416:
 </​WRAP>​ </​WRAP>​
 **6. //​menuTimeout//​** \\  **6. //​menuTimeout//​** \\ 
-Timeout in seconds for lock screen when the user is inactive. The timeout can be set from 0 to 255 seconds. 0 means no lock screen.\\ ​\\ +Timeout in seconds for lock screen when the user is inactive. The timeout can be set from 0 to 255 seconds. 0 means no lock screen.\\ ​ 
 +<WRAP group 50%> 
 +^Value ​ ^Description ​ ^ 
 +|0  |No timeout. ​ | 
 +|10  |Menu timeout 10 sec.  | 
 +|20  |Menu timeout 20 sec. (Default) ​ | 
 +|30  |Menu timeout 30 sec.  | 
 +|40  |Menu timeout 40 sec.  | 
 +|50  |Menu timeout 50 sec.  | 
 +|60  |Menu timeout 60 sec.  | 
 +</​WRAP>​
 **7. //​msgTimeout//​** \\  **7. //​msgTimeout//​** \\ 
-Message timeout in milliseconds. The timeout can be set from 500 to 5000 milliseconds.\\ ​\\ +Message timeout in milliseconds. The timeout can be set from 500 to 5000 milliseconds.\\ ​ 
 +<WRAP group 50%> 
 +^Value ​ ^Description ​ ^ 
 +|500  |Message timeout 500 msec.  | 
 +|1000  |Message timeout 1 sec.  | 
 +|2000  |Message timeout 2 sec. (Default) ​ | 
 +|3000  |Message timeout 3 sec.  | 
 +|4000  |Message timeout 4 sec.  | 
 +|5000  |Message timeout 5 sec.  | 
 +</​WRAP>​
 **8. //​backlightTimeout//​** \\  **8. //​backlightTimeout//​** \\ 
-Backlight timeout in seconds. \\ \\ +Backlight timeout in seconds. \\  
 +<WRAP group 50%> 
 +^Value ​ ^Description ​ ^ 
 +|0  |Backlight timeout 0 sec.  | 
 +|10  |Backlight timeout 10 sec.  | 
 +|20  |Backlight timeout 20 sec. (Default) ​ | 
 +|30  |Backlight timeout 30 sec.  | 
 +|40  |Backlight timeout 40 sec.  | 
 +|50  |Backlight timeout 50 sec.  | 
 +|60  |Backlight timeout 60 sec.  | 
 +</​WRAP>​
 **9. //​displayDateTime//​** \\  **9. //​displayDateTime//​** \\ 
 Decides whether to display clock on screen. \\ \\  Decides whether to display clock on screen. \\ \\ 
Line 449: Line 479:
 Home screen layout(Going to apply later, not used currently). \\ \\  Home screen layout(Going to apply later, not used currently). \\ \\ 
 **16. //​tnaIcon//​** \\  **16. //​tnaIcon//​** \\ 
-Icon displayed on the device corresponding ​to the job code. \\ \\ +Icon displayed on the device corresponding ​TNA key. \\ \\ 
-**17. //​reserved1//​** \\ +**17. //​useScreenSaver//​** \\  
 +''​FaceStation 2'',​ ''​FaceStation F2''​ If set true, you can activate the screensaver. \\ \\ 
 +**18. //​reserved1//​** \\ 
 Reserved space. \\  Reserved space. \\ 
  
Line 812: Line 844:
 </​WRAP>​ </​WRAP>​
 **2. //​channelIndex//​** \\  **2. //​channelIndex//​** \\ 
-Communication channel index of the RS-485 network. \\ \\+(non configurable index) ​Communication channel index of the RS-485 network. \\ \\
 **3. //​useRegistance//​** \\  **3. //​useRegistance//​** \\ 
-Decides whether to use a resistance. \\ \\+Registance flag - no effect on operation. \\ \\
 **4. //​numOfDevices//​** \\  **4. //​numOfDevices//​** \\ 
 Number of slave devices.\\ \\ Number of slave devices.\\ \\
Line 1636: Line 1668:
 |1  |Outdoor ​ | |1  |Outdoor ​ |
 |2  |Automatic ​ | |2  |Automatic ​ |
 +|3  |[+V2.8] Not used ''​(FaceStation F2)'' ​ |
 </​WRAP>​ </​WRAP>​
 **3. //​enrollThreshold//​** \\  **3. //​enrollThreshold//​** \\ 
Line 1658: Line 1691:
 |0  |Off  | |0  |Off  |
 |1  |Low  | |1  |Low  |
-|2  |Basic  |+|2  |Medium ​ |
 |3  |High  | |3  |High  |
 </​WRAP>​ </​WRAP>​
Line 2188: Line 2221:
  
     uint8_t thermalFormat;​     uint8_t thermalFormat;​
-    uint8_t reserved2[3];+    uint8_t reserved2;
  
-    uint16_t ​thermalThreshold;+    uint16_t ​thermalThresholdLow;​ 
 +    uint16_t thermalThresholdHigh;
     uint8_t maskDetectionLevel;​     uint8_t maskDetectionLevel;​
     uint8_t auditTemperature;​     uint8_t auditTemperature;​
Line 2196: Line 2230:
     uint8_t useRejectSound;​     uint8_t useRejectSound;​
     uint8_t useOverlapThermal;​     uint8_t useOverlapThermal;​
-    uint8_t ​reserved4;+    uint8_t ​useDynamicROI;
     uint8_t faceCheckOrder;​     uint8_t faceCheckOrder;​
 } BS2FaceConfigExt;​ } BS2FaceConfigExt;​
Line 2238: Line 2272:
 5. //​reserved2//​ \\  5. //​reserved2//​ \\ 
 Reserved \\ \\ Reserved \\ \\
-6. //thermalThreshold// \\ +6. //thermalThresholdLow// \\ 
-This is the standard ​value for determining high temperature and must be entered as a value multiplied by 100 of the temperature to be set. \\+''​Supported version''​ : ''​FaceStation F2 V1.0.2'',​ ''​FaceStation 2 V1.5.0'' ​\\  
 +This is the range value for determining high temperature and must be entered as a value multiplied by 100 of the temperature to be set. \\
 Also, you can only enter in degrees Celsius. \\ Also, you can only enter in degrees Celsius. \\
-This value is the basis for the denial of authentication,​ and the setting range is between ​3000(30º) and 4500(45º). \\ \\ +This value is the basis for the denial of authentication,​ and the setting range is between ​100 () and 4500 (45º). \\ 
- +The default value is 3200 (32º), and if a value larger or smaller than the setting range is entered, the default value a set to 3200 (32º). ​\\ 
-7. //​maskDetectionLevel//​ \\+And you must set a value less than thermalThresholdHigh. \\ \\ 
 +7. //​thermalThresholdHigh//​ \\ 
 +This is the range value for determining high temperature and must be entered as a value multiplied by 100 of the temperature to be set. \\ 
 +Also, you can only enter in degrees Celsius. \\ 
 +This value is the basis for the denial of authentication,​ and the setting range is between 100 (1º) and 4500 (45º). \\ 
 +The default value is 3800 (38º), and if a value larger or smaller than the setting range is entered, the default value a set to 3800 (38º). \\ 
 +And you must set a value greater than thermalThresholdLow. \\ \\ 
 +8. //​maskDetectionLevel//​ \\
 ''​FaceStation F2''​ Sets the mask detection level. The detecting level is based on internal setting value. \\ ''​FaceStation F2''​ Sets the mask detection level. The detecting level is based on internal setting value. \\
 ''​FaceStation 2''​ This setting is ignored. \\  ''​FaceStation 2''​ This setting is ignored. \\ 
Line 2253: Line 2295:
 |3  |Detection level (Very high)  |  | |3  |Detection level (Very high)  |  |
 </​WRAP>​ </​WRAP>​
-8. //​auditTemperature//​ \\ +9. //​auditTemperature//​ \\ 
 Decides whether the measured temperature is recorded in the log or not. \\ \\ Decides whether the measured temperature is recorded in the log or not. \\ \\
-9. //​useRejectSound//​ \\+10. //​useRejectSound//​ \\
 Decides whether it sounds when rejecting a user due to thermalThreshold or maskDetectionLevel. \\ \\ Decides whether it sounds when rejecting a user due to thermalThreshold or maskDetectionLevel. \\ \\
-10. //​useOverlapThermal//​ \\+11. //​useOverlapThermal//​ \\
 Displays a thermal image overlaid on the screen. \\ \\ Displays a thermal image overlaid on the screen. \\ \\
-11. //reserved4// \\  +12. //useDynamicROI// \\  
-Reserved ​\\ \\ +When set to true, when measuring temperature,​ the user's forehead is found and measured, not a fixed area. \\ \\ 
-12. //​faceCheckOrder//​ \\ +13. //​faceCheckOrder//​ \\ 
 It defines the sequence of thermal check and mask detection and authentication. \\ It defines the sequence of thermal check and mask detection and authentication. \\
 Because the user should touch the device in the case of ID combination authentication or PIN combination authentication,​\\ Because the user should touch the device in the case of ID combination authentication or PIN combination authentication,​\\
Line 2267: Line 2309:
 <WRAP group 50%> <WRAP group 50%>
 ^Value ​ ^Description ​ ^Default ​ ^ ^Value ​ ^Description ​ ^Default ​ ^
-|0  |Temperature check or Mask detection check before ​authentication | Default ​ | +Authentication before ​Temperature check or Mask detection check  
-|1  |Authentication ​before ​Temperature check or Mask detection check  ​| ​ | +|0  |Check after authentication | Default ​ | 
-|2  |No authentication. Only Temperature check or Mask detection ​check  |  |+|1  |Check before ​authentication ​ ​| ​ | 
 +|2  |No authenticationcheck only  ​| ​ |
 </​WRAP>​ </​WRAP>​
  
Line 2293: Line 2336:
 </​code>​ </​code>​
 1. //​distance//​ \\  1. //​distance//​ \\ 
-The distance measured by the thermal imaging camera. The unit is cm, and the default is 70. \\ \\+The distance measured by the thermal imaging camera. The unit is cm, and the default is 100. \\ \\
 2. //​emissionRate//​ \\ 2. //​emissionRate//​ \\
-The rate of the subject reflecting heat. \\+The emissivity ​of the subject reflecting heat. \\
 It is recommended to enter within the [95/97/98] range. If the subject is a human, 98 is recommended. \\ \\ It is recommended to enter within the [95/97/98] range. If the subject is a human, 98 is recommended. \\ \\
 3. //roi// \\ 3. //roi// \\