Differences
This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
en:configuration_api [2020/11/23 11:28] kkshin [BS2DisplayConfig] |
en:configuration_api [2021/03/16 11:07] yjjung [BS2FaceConfigExt] |
||
---|---|---|---|
Line 450: | Line 450: | ||
Home screen layout(Going to apply later, not used currently). \\ \\ | Home screen layout(Going to apply later, not used currently). \\ \\ | ||
**16. //tnaIcon//** \\ | **16. //tnaIcon//** \\ | ||
- | Icon displayed on the device corresponding to the job code. \\ \\ | + | Icon displayed on the device corresponding TNA key. \\ \\ |
**17. //useScreenSaver//** \\ | **17. //useScreenSaver//** \\ | ||
''FaceStation 2'', ''FaceStation F2'' If set true, you can activate the screensaver. \\ \\ | ''FaceStation 2'', ''FaceStation F2'' If set true, you can activate the screensaver. \\ \\ | ||
Line 815: | Line 815: | ||
</WRAP> | </WRAP> | ||
**2. //channelIndex//** \\ | **2. //channelIndex//** \\ | ||
- | Communication channel index of the RS-485 network. \\ \\ | + | (non configurable index) Communication channel index of the RS-485 network. \\ \\ |
**3. //useRegistance//** \\ | **3. //useRegistance//** \\ | ||
- | Decides whether to use a resistance. \\ \\ | + | Registance flag - no effect on operation. \\ \\ |
**4. //numOfDevices//** \\ | **4. //numOfDevices//** \\ | ||
Number of slave devices.\\ \\ | Number of slave devices.\\ \\ | ||
Line 1661: | Line 1661: | ||
|0 |Off | | |0 |Off | | ||
|1 |Low | | |1 |Low | | ||
- | |2 |Basic | | + | |2 |Medium | |
|3 |High | | |3 |High | | ||
</WRAP> | </WRAP> | ||
Line 2243: | Line 2243: | ||
Reserved \\ \\ | Reserved \\ \\ | ||
6. //thermalThresholdLow// \\ | 6. //thermalThresholdLow// \\ | ||
- | ''Supported version : FaceStation F2 V1.0.2, FaceStation 2 V1.5.0'' \\ | + | ''Supported version'' : ''FaceStation F2 V1.0.2'', ''FaceStation 2 V1.5.0'' \\ |
This is the range value for determining high temperature and must be entered as a value multiplied by 100 of the temperature to be set. \\ | This is the range value for determining high temperature and must be entered as a value multiplied by 100 of the temperature to be set. \\ | ||
Also, you can only enter in degrees Celsius. \\ | Also, you can only enter in degrees Celsius. \\ | ||
- | This value is the basis for the denial of authentication, and the setting range is between 3000(30º) and 4500(45º). \\ | + | This value is the basis for the denial of authentication, and the setting range is between 100 (1º) and 4500 (45º). \\ |
- | The default value is 3200(32º), and if a value larger or smaller than the setting range is entered, the default value a set to 3200(32º). \\ | + | The default value is 3200 (32º), and if a value larger or smaller than the setting range is entered, the default value a set to 3200 (32º). \\ |
And you must set a value less than thermalThresholdHigh. \\ \\ | And you must set a value less than thermalThresholdHigh. \\ \\ | ||
7. //thermalThresholdHigh// \\ | 7. //thermalThresholdHigh// \\ | ||
This is the range value for determining high temperature and must be entered as a value multiplied by 100 of the temperature to be set. \\ | This is the range value for determining high temperature and must be entered as a value multiplied by 100 of the temperature to be set. \\ | ||
Also, you can only enter in degrees Celsius. \\ | Also, you can only enter in degrees Celsius. \\ | ||
- | This value is the basis for the denial of authentication, and the setting range is between 3000(30º) and 4500(45º). \\ | + | This value is the basis for the denial of authentication, and the setting range is between 100 (1º) and 4500 (45º). \\ |
- | The default value is 3800(38º), and if a value larger or smaller than the setting range is entered, the default value a set to 3800(38º). \\ | + | The default value is 3800 (38º), and if a value larger or smaller than the setting range is entered, the default value a set to 3800 (38º). \\ |
And you must set a value greater than thermalThresholdLow. \\ \\ | And you must set a value greater than thermalThresholdLow. \\ \\ | ||
8. //maskDetectionLevel// \\ | 8. //maskDetectionLevel// \\ | ||
Line 2279: | Line 2279: | ||
<WRAP group 50%> | <WRAP group 50%> | ||
^Value ^Description ^Default ^ | ^Value ^Description ^Default ^ | ||
- | |0 |Temperature check or Mask detection check before authentication | Default | | + | Authentication before Temperature check or Mask detection check |
- | |1 |Authentication before Temperature check or Mask detection check | | | + | |0 |Check after authentication | Default | |
- | |2 |No authentication. Only Temperature check or Mask detection check | | | + | |1 |Check before authentication | | |
+ | |2 |No authentication, check only | | | ||
</WRAP> | </WRAP> | ||