2023-06-08
1. Supports a new SE processor and new firmware.
2. Improved the structure to prevent authentication fail caused by broken database or cache memory.
3. Improved to select and update only the desired information when updating user information. (Compatible with BioStar v2.9.0 or higher)
1. When authenticating with a BLE mobile card running on iOS, authentication fails and the device restarts intermittently. (Affects version: v1.0.0)
2. Card authentication performance being slower than the previous versions. (Affects version: v1.5.0)
3. Improved the OSDP ID to also be deleted when a security tamper occurs on the device connected as a slave. (Affects version: v1.0.0)
4. When using the card to authenticate to the device, the card that was normally authenticated fails intermittently. (Affects version: v1.0.0)
5. Applying an invalid custom resource causes the device to restart. (Affects version: v1.0.0)
6. Deleting all users included in an access group in BioStar 2 does not delete the access group from the device’s user information. (Affects version: v1.0.0)
7. Device does not recognize certain HID iCLASS Seos cards. (Affects version: v1.0.0)
8. When the LAN cable connected to the device is disconnected and reconnected, it takes a long time for IP to be assigned by DHCP. (Affects version: v1.0.0)
9. Door Locked event occurs when input signal gets detected while configured to Arm/Disarm by input signal. (Affects version: v1.0.0)
10. Intermittently, the door does not open even if authentication succeeds when the door uses the slave device’s relay. (Affects version: v1.0.0)