BioStar uses several ports to make a device connection and data communication. Basically, the used network ports by BioStar and Suprema device are different according to the device connection mode to BioStar server or client.
With direct mode, the device connection is made to the client and the client makes a connection to the server. This is why you cannot see the device from another client when it’s already connected to the client. In this case, the port number is like below.
With the server mode, the device makes a connection to the server directly, and makes an auto reconnection by using server API.
Regardless of Direct or Server mode, the below commands made from the client uses UDP 51110 port to send packets to the device.
So, when one of the above commands is in active, the below ports are to be used.
Therefore, in order to make BioStar related port an exception of firewall, it’s necessary to open the below ports with the server mode.
TCP Port: 1470,1471,1480
UDP Port: 51110
Please note that the direct mode is for temp use, and it’s not recommended for normal system operation.