2022-10-21
1. Improved motion detection performance for low-light environments.
2. Improved Visual Face matching algorithm.
3. Improved all pop-up messages displayed on the device to operate according to the time set in Message Timeout.
4. Fixed Korean and English strings in the RTSP menu.
1. When upgrading resources or firmware from BioStar 2, the device could not check the progress of the upgrade because no information was displayed. (Affects version: v1.0.0)
2. When synchronizing multiple users to a device in BioStar 2 and then restarting the device, the User Usage on the device displays a different number of visual faces than the number of synchronized. (Affects version: v1.0.0)
3. When entering the device detail page after adding a logo image to the device connected as a slave, an Invalid payload error occurs and the RS-485 get disconnected. (Affects version: v1.0.0)
4. When Device Hashkey Management is set to Use in BioStar 2 and migration proceeds, all users are deleted from the device, but a delete notification pop-up is not displayed. (Affects version: v1.0.0)
5. Device hangs intermittently and then restarts. (Affects version: v1.0.0)
6. When entering the Wireless, the new SSID does not appear, but only the previously searched SSID appears. (Affects version: v1.0.0)
7. When enrolling a visual face or card on a device using the BioStar 2, the scan screen is not visible and the screen saver state remains. (Affects version: v1.0.0)
8. When the call button on the main screen is pressed with only one extension number stored in the device, it does not connect directly. (Affects version: v1.0.0)
9. In Edit User, if you select Extended Private Auth Mode as ID + Fingerprint/PIN and press OK, the fingerprint icon is incorrectly displayed as a face icon in the Extended Private Auth Mode list. (Affects version: v1.0.0)
10. Authentication failure occurs when authenticating with AoC with private auth mode set to Card + Face. (Affects version: v1.0.0)
11. When the device is restarted via BioStar 2, only a notification sound plays and the restart pop-up message does not appear. (Affects version: v1.0.0)
12. Firmware upgrade via USB restarts the device without a success or failure popup message. (Affects version: v1.0.0)
13. In BioStar 2's T&A menu, the Schedule display part is blank when creating a T&A Code with a Schedule other than Always and selecting the T&A Code on the device. (Affects version: v1.0.0)
14. Memory usage incorrectly displayed in DRAM Usage in Memory Info. (Affects version: v1.0.0)
15. When entering the menu from a device connected as a slave, a normal menu touch sound plays instead of a warning sound. (Affects version: v1.0.0)
16. When enrolling a visual face in the USER menu in BioStar 2, when the scan waiting time exceeded while enrolling the 1st face and then scanning the 2nd face, the face enrolled in the 1st appears. (Affects version: v1.0.0)
17. If the network is connected to a wireless LAN and then enters Wireless again after changing to an ethernet connection, the wireless AP list is not displayed. (Affects version: v1.0.0)
18. Device hangs intermittently when Wiegand Input/Output setting is set to Output. (Affects version: v1.0.0)
19. Extension number gets stored in the phonebook while exceeding the maximum characters in the Display Name of the Intercom settings. (Affects version: v1.0.0)
20. When entering the edit screen by selecting the Auth Mode set in the device's Auth Mode, the touch sound does not play. (Affects version: v1.0.0)
21. Device connected as a slave intermittently operates while disconnected. (Affects version: v1.0.0)
22. An error occurs when calling the extension number when the Intercom of the device is set to Not Use via BioStar 2 while the list of extension numbers is displayed by pressing the call button on the main screen of the device. (Affects version: v1.0.0)
23. In the screen to set the Schedule in Auth Mode, the already created schedule is shown as a duplicate. (Affects version: v1.0.0)
24. When the device is in the middle of Factory Default process, the device hangs while loading. (Affects version: v1.0.0)
25. When the Language of the device is set to Custom, the Voice Instruction menu part of Sound displays as a blank. (Affects version: v1.0.0)
26. When the Time Zone of the master device connected via RS-485 is changed, the Time Zone of the slave device does not change. (Affects version: v1.0.0)
27. When authenticating with a mobile card set to NFC, authentication fails and the device restarts intermittently (Affects version: v1.0.0)
28. The correct message does not appear when an unenrolled card is scanned with Filter set to Card in the user search (Affects version: v1.0.0)
29. The pop-up to set the Filter on the EVENT LOG search screen does not disappear even after the time set in the device's Menu Timeout has elapsed. (Affects version: v1.0.0)
30. Event log is not logged when Time Zone is changed on the device. (Affects version: v1.0.0)
31. When scanning Visual Face via BioStar 2 while the device is in the SETTINGS, the scan screen does not close on the device even after scanning is complete. (Affects version: v1.0.0)
32. Baud Rate selection pop-up appears when touching an empty space at the bottom of the Ethernet screen. (Affects version: v1.0.0)
33. When sending a user whose card is duplicated with another user from BioStar 2 to the device, the user is deleted from the device. (Affects version: v1.0.0)
34. When the firmware is upgraded for each device connected as master-slave, the slave device completes normally, but the master device hangs. (Affects version: v1.0.0)
35. RTSP connection termination event log is not logged and RTSP icon is not deleted even after setting RTSP to Not Use. (Affects version: v1.0.0)
36. Does not restart on Restore Default due to setup error. (Affects version: v1.0.0)
37. Date & Time not displayed correctly. (Affects version: v1.0.0)
38. When adding a user, the backlight does not turn off when waiting without card input on the card scan screen. (Affects version: v1.0.0)
39. Search does not work when searching by Start Time and End Time in EVENT LOG. (Affects version: v1.0.0)
40. An incorrect schedule displays in the Edit Auth Mode. (Affects version: v1.0.0)
41. If you scan a Wiegand format card that is not set when enrolling a card to a user and then scan a normal card, it will not be scanned. (Affects version: v1.0.0)
42. The device retains the call screen even after the recipient terminates the call. (Affects version: v1.0.0)
43. WiFi MAC does not appear in DASHBOARD and Device Info for Wi-Fi supported models. (Affects version: v1.0.0)
44. On the scan card screen, the background allows touch and the face can get authenticated. (Affects version: v1.0.0)
45. When enrolling a card in BioStar 2, after selecting Write Smart Card, the device restarts while waiting for scan. (Affects version: v1.0.0)
46. An issue occurs when upgrading the firmware of a slave device from BioStar 2 while the device is connected as Master-Slave. (Affects version: v1.0.0)
47. The OK button does not work when repeatedly searching the EVENT LOG. (Affects version: v1.0.0)
48. Intermittently, the image log is logged abnormally. (Affects version: v1.0.0)
49. Speaker turns on and off repeatedly when multiple sound files are played continuously. (Affects version: v1.0.0)
50. The device restarts abnormally when the firmware is upgraded while the device is locked. (Affects version: v1.0.0)
51. Wireless connection intermittently disconnects when sending Visual face from BioStar 2 to device. (Affects version: v1.0.0)
52. The screen turns off at the time set in Menu Timeout during an Intercom call. (Affects version: v1.0.0)
53. When deleting all logs, image logs does not get deleted. (Affects version: v1.0.0)
54. VFMCore version information is not displayed when long-touching the MAC in Device Info. (Affects version: v1.0.0)
55. When issuing a Smart Card, if a fingerprint/face is included in Private Auth Mode, the issuance fails intermittently in a specific card. (Affects version: v1.0.0)