In general, a project site where it is hard to connect the network or the reader is operated standalone, the information on Users and Logs can be imported or exported using USB memory for the purpose of T&A. For example, you can enroll new user through BioStar 2 server in the head office. Then, after exporting the user data to USB memory, the user information stored in USB memory can be imported to the reader which is located in real-site away from the main office. Like this scenario, the logs are also exported from the device operated standalone and then imported to BioStar 2 server in order to apply to T&A report for the employee.
From BioStar v2.6.2, below features are introduced.
1. Go to User tab in BioStar 2.
2. Select the users who you want to export.
3. Click button located on the right side.
4. If you click “Data File Export”, you can save the files about users in either USB memory or allocated path of PC.
5. Then, you can see the files about user.
6. At this point, below information will be transferred from BioStar 2 server.
7. The user data exported from BioStar 2 server can be imported to Suprema reader through the USB memory.
1. Go to User tab in BioStar 2.
2. Select the users who you want to import.
3. Click button located on the right side.
4. If you click “Data File Import”, you can save the files about users in either USB memory or allocated path of PC.
5. You can select a file about user information which is saved in USB memory.
1. Go to Monitoring tab in BioStar 2.
2. Go to Event Log section.
3. Click button located on the right side.
4. If you click “Data File Import”, you can save the files about users in either USB memory or allocated path of PC.
5. Select the log file saved in USB memory as TGZ file format.
6. Then, you can see the event logs exported from the device in BioStar 2 Server with success message.