While using an access control system, there are requirements to unlock the entrance or doors for a certain time for guests and employees to pass by easily. Also, there are needs to lock the doors during a time nobody should be inside the building or a facility. In BioStar 2, you can use the Scheduled Lock/Unlock Zone to meet your requirements.

To use the Scheduled Lock/Unlock zone, the BioStar 2 AC Standard License has to be activated.
How to Activate Biostar 2 License

The Scheduled Lock/Unlock zone is a feature based on a door not the device. To create a door using the device.
How to add and configure doors

How to configure Scheduled Lock Zone

1) Go to ZoneAdd Zone → Select Scheduled LockApply.


2) Configure the detail settings of the Scheduled Lock Zone.


2-1) If Door Lock Type is set as Exit Allowed, the users will be able to exit using the exit device of the door. It can be set as Access not allowed.
2-2) Select a predefined schedule or create a schedule for the Scheduled Lock Zone.
2-3) On the Alarm tab, you can select the action that will be done when someone tries to authenticate during the scheduled lock time.
2-4) You can set a Bypass Group which is an access group that is allowed to pass the door even the scheduled lock is activated on the configured time.


3) Click the Apply button.




How to configure Scheduled Unlock Zone

1) Go to ZoneAdd Zone → Select Scheduled UnlockApply.


2) Configure the detail settings of the Scheduled Unlock Zone.

2-1) The Scheduled Unlock Zone has a feature where you can set it to start by a user authentication. If you set this option as active, a user who belongs to the access group configured to the Scheduled Unlock Authentication has to authenticate during the configured time to start the Scheduled Unlock. This is to prevent the door to be opened when there is nobody in charge at the site.


3) Click the Apply button.