Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
en:intelligent_slave_support [2021/04/26 15:09]
jhlee2 created
en:intelligent_slave_support [2024/01/30 15:30] (current)
jhlee2 [Supported device and firmware information]
Line 1: Line 1:
 ====== Intelligent Slave Support ====== ====== Intelligent Slave Support ======
-Previously Suprema BioStar 2 FW supports ​the below OSDP slave usage.+PreviouslySuprema BioStar 2 FW supported ​the below OSDP slave usage.
 \\ \\
   - 3rd party ACU holds the card with the biometric information and the Suprema reader is an OSDP slave reader.   - 3rd party ACU holds the card with the biometric information and the Suprema reader is an OSDP slave reader.
-  - Suprema device handles the Access On Card(Template On Card) and sends the result to 3rd party ACU.+  - Suprema device handles the Access On Card (Template On Card) and sends the result to the 3rd party ACU.
 \\ \\
-The customers who want to manage ​the user information ​to Suprema device and send out the card data of the verified ​user from Suprema device ​are not available ​to use Suprema device without FW change.+The customers who want to manage ​their user information ​on Suprema device and send out the card data of the verified ​users from Suprema device ​can not to use Suprema device without FW change.
 \\ \\
 From v2.8.10 with upcoming FW, Suprema supports Intelligent Slave Feature. From v2.8.10 with upcoming FW, Suprema supports Intelligent Slave Feature.
Line 18: Line 18:
 \\ \\
 ===== Supported device and firmware information ===== ===== Supported device and firmware information =====
-* BioStar 2.8.10 or later is mandatorily required+* BioStar 2.8.10 or above are needed
-{{ :en:2.8.10-1-2.png?​nolink ​|}}+- Reference the article below:\\ 
 + ​[[https://support.supremainc.com/​en/​support/​solutions/​articles/​24000068102--biostar-2-firmware-list-of-supporting-intelligent-slave|[BioStar 2] Firmware List of Supporting Intelligent Slave ]] 
 +\\ 
 +^  Device ​ ^  Firmware ​ ^ 
 +|BioEntry W2 |v1.6.3 or later | 
 +|BioStation L2 |v1.6.or later | 
 +|BioEntry P2 |v1.4.1 or later | 
 +|XPass 2 |v1.2.3 or later | 
 +|FaceStation F2 |v1.1.2 or later | 
 +|BioLite N2 |v1.4.1 or later | 
 +|X-Station ​2 |v1.1.0 or later | 
 +|BioStation 3 |v1.0.0 or later | 
 +|BioStation 2a |v1.0.0 or later |
 \\ \\
 ===== How to configure Intelligent Slave ===== ===== How to configure Intelligent Slave =====
Line 30: Line 42:
 {{ :​en:​2.8.10-1-4.png?​nolink |}} {{ :​en:​2.8.10-1-4.png?​nolink |}}
 \\ \\
-Step 2-1. Confirm if the baud rate of RS485 is the same as the baud rate of 3rd party ACU. Usually, the default of 3rd party ACU is 9600. Please set the same parameter of the Suprema device from the baud rate of 3rd party ACU.+Step 2-1. Confirm if the baud rate of RS485 is the same as the baud rate of the 3rd party ACU. Usually, the default of the 3rd party ACU is 9600. Please set the same parameter of the Suprema device from the baud rate of 3rd party ACU.
 {{ :​en:​2.8.10-1-5.png?​nolink |}} {{ :​en:​2.8.10-1-5.png?​nolink |}}
 <callout type="​primary"​ icon="​true"> ​ <callout type="​primary"​ icon="​true"> ​
Line 37: Line 49:
 \\ \\
 Step 3. Check the Intelligent Slave at the end of the network on the device detail page. Step 3. Check the Intelligent Slave at the end of the network on the device detail page.
-  * Exception Code: The default is [Disabled]. Suprema device can send to aggregate accurate logs in exceptional situations such as authentication failures or the no card of the verified user information. Depending on the system requirement of 3rd party ACU, you can enable this option and set it in decimal or hexadecimal. You can enter decimal numbers from 0 to 18446744073709551615,​ and you can enter hexadecimal numbers from 0 to FFFFFFFFFFFFFFFF or hexadecimal characters. (up to 8 bytes)+  * Exception Code: The default is [Disabled]. Suprema device can send to aggregate accurate logs in exceptional situations such as authentication failures or the no card of the verified user information. Depending on the system requirement of the 3rd party ACU, you can enable this option and set it in decimal or hexadecimal. You can enter decimal numbers from 0 to 18446744073709551615,​ and you can enter hexadecimal numbers from 0 to FFFFFFFFFFFFFFFF or hexadecimal characters. (Up to 8 bytes)
 {{ :​en:​2.8.10-1-6.png?​nolink |}} {{ :​en:​2.8.10-1-6.png?​nolink |}}
 \\ \\
-  * Output Info: You can output ​between ​Card ID and User ID when authentication is successfully done.+  * Output Info: You can output ​either your Card ID or User ID when authentication is successfully done.
 {{ :​en:​2.8.10-1-7.png?​nolink |}} {{ :​en:​2.8.10-1-7.png?​nolink |}}
 \\ \\
Line 47: Line 59:
 \\ \\
 \\ \\
-Step 4. Create a new user in BioStar 2 to synchronize the user data to the connected Suprema device. In addition, check if there is user verification success. ​+Step 4. Create a new user in BioStar 2 to synchronize the user data to the connected Suprema device. In addition, check if there is user verification success ​log
 \\ \\
 \\ \\
-Step 5. Connect your device ​with 3rd party ACU through RS485(OSDP) and check the operation.+Step 5. Connect your device ​to the 3rd party ACU through RS485(OSDP) and check the operation.