Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
en:how_to_configure_one_device_legacy_mode [2021/12/17 10:29]
peterk
en:how_to_configure_one_device_legacy_mode [2021/12/29 14:40] (current)
peterk
Line 1: Line 1:
-===== How to configure ​Secure Tamper ​=====+===== How to configure ​One Device(Legacy) Mode =====
 ---- ----
-When **Tamper On** option is ON: If the device is separated from the bracket (**Tamper On** event happens)the information on all users, logs, encryption key, and SSL certificates ​configured in the device will be deleted promptly. \\ \\+In BioStar 2.5.0 or below, you can process ​the Wiegand input signal when you add a 3rd party device ​as a Wiegand device. This means that you cannot regard the 3rd-party device as one device combined with a Suprema reader.  
 +\\For example, if you should use a special card that is not supported by Suprema readers with the authentication mode “Card + Fingerprint”,​ you may connect a 3rd-party reader with a Suprema reader via Wiegand. At this point, many customers would like to deal with the card authentication event as if it is generated by one device. \\ 
 +From BioStar 2.6.0, we introduced a new feature ​**“One device Mode”**. In this featureif a Wiegand input is configured in the device ​setting and then the Wiegand signal is generated without adding a 3rd-party reader as a Wiegand reader to the master device, the Wiegand signal ​will be received in the master device (Suprema reader). \\ \\
  
-Supported device: \\ +{{:en:biostar2_one_device_mode_1.png?​nolink&​1200|}} \\ \\
-<callout type="​primary"​ icon="​true">​  +
-BioStation 2 V1.6.0 or above +
-BioStation A2 V1.5.0 or above +
-BioStation L2 V1.4.0 or above +
-CoreStation V1.1.0 or above +
-BioEntry P2 V1.1.0 or above +
-BioLite N2 V1.0.0 or above +
-BioEntry W2 V1.2.0 or above +
-BioEntry R2 V1.0.0 or above +
-XPass D2 V1.0.0 or above +
-FaceStation 2 V1.1.0 or above +
-FaceStation F2 V1.0.0 or above +
-FaceLite V1.0.0 or above +
-X-Station 2 V1.0.0 or above +
-</​callout>​ +
-{{:en:biostar2_secure_tamper_6.png?​nolink&​500|}}  +
-\\ \\+
  
-<callout type="​tip"​ icon="​true">​  +==== How to configure? ====
-  * Once the **Tamper On** event is generated, the users saved in BioStar 2 can no longer be synchronized with the device. In this case, you should transfer users to the device manually. +
-  * Slave device is not supported. +
-</​callout>​ \\ \\+
  
-==== How to configure ​==== +You can configure ​One Device Mode with no additional task. You just have to connect the 3rd-party device with a Suprema reader using a Wiegand cable. \\ \\ 
-There are two cases to configure. \\ \\ +1. Connect a 3rd-party device with a Suprema reader using a Wiegand cable. At this point, the Wiegand input port should be connected in the Suprema reader. \\ 
-=== Case 1: === +2. Set connection mode to either ​**Master** or **Default**. \\
-If you set **Secure communication with device** ​to **Not Use** in **Setting** > **SERVER**, you should follow the below instructions to configure secure tamper. \\+
  
-{{:​en:​biostar2_secure_tamper_1.png?​nolink&​600|}} \\ \\+<callout type="​info"​ icon="​true">​ 
 +One Device (Legacy) Mode supports all types of devices if the Wiegand input setting is configured 
 +The **SLAVE** device does not support One Device Mode. Only Master or Default (Standalone) can be supported. 
 +</​callout> ​\\ 
  
-1Go to Device ​**Setting** **Advanced**. \\ +3Change ​**Format Type** into **Wiegand** and select the suitable Wiegand formatIn addition, select ​**Wiegand Card Format**. \\
-2. Change **Secure Tamper** into **On**. \\+
  
-{{:en:biostar2_secure_tamper_2.png?​nolink&​1000|}} \\ \\+{{:en:biostar2_one_device_mode_2.png?​nolink&​1000|}} \\ \\
  
-3When the Tamper On event happensyou can see the below message in BioStar 2. \\+4In the Advanced Settingconfigure **Wiegand Input/​Output** into **Input** then select ​the suitable **In/Out Format**. \\
  
-{{:en:biostar2_secure_tamper_3.png?​nolink&​500|}} \\ \\+{{:en:biostar2_one_device_mode_3.png?​nolink&​1000|}} \\ \\
  
-Then, you can see the below event logs in the Monitoring sectionEspecially, if you check the users and logs on the device directly, they would be deleted completely. \\ +5We will test “Card + Fingerprint” authentication ​with these settings. \\ 
- +5-1In Suprema readerwe configure ​Auth Mode to “Card + Fingerprint”. \\
-{{:​en:​biostar2_secure_tamper_4.png?​nolink&​1200|}} \\ \\ \\ +
- +
- +
-=== Case 2: === +
-If you set **Secure communication ​with device** to **Use** in **Setting** > **SERVER**, you can see additional options below. Please see **Server & device encryption key manual management**. \\ +
- +
-{{:​en:​biostar2_secure_tamper_5.png?​nolink&​1200|}} \\ \\ +
- +
-If you change **Server & device encryption key manual management** into **Use**you can see below warning message.  +
-\\ +
-Please note that, if you configure ​this setting, the function **Secure Tamper** will be applied automaticallyBefore you apply this setting, please be careful. +
- +
-{{:​en:​biostar2_secure_tamper_7.png?​nolink&​600|}} \\ \\+
  
 +{{:​en:​biostar2_one_device_mode_4.png?​nolink&​1000|}} \\ \\
  
 +5-2. Once you succeed in card authentication on a 3rd-party device, the Wiegand input signal will be sent to the Suprema reader. After that, the Suprema reader requests you to scan fingerprints on it. If you succeeded in scanning fingerprints on the Suprema reader, the below event will happen as if “Card + Fingerprint” authentication is generated in one device. \\
  
 +{{:​en:​biostar2_one_device_mode_5.png?​nolink&​1200|}} \\ \\ \\
  
 +=== Supported Device & Firmware version: === 
 +{{:​en:​biostar2_one_device_mode_6.png?​nolink&​500|}} \\ \\
  
 +<callout type="​info"​ icon="​true">​
 +** New devices that support this feature: ** \\
 +   * FaceLite 2 V1.0.0 or above \\
 +   * XPass 2 V1.0.0 or above \\
 +   * FaceStation F2 V1.0.0 or above \\
 +   * X-Station 2 V1.0.0 or above \\
 +</​callout>​ \\