Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
en:how_to_configure_trigger_and_action [2020/06/02 09:46]
kate
en:how_to_configure_trigger_and_action [2022/12/28 16:47] (current)
phit
Line 1: Line 1:
 {{tag>"​System Configuration"​ "​BioStar 2" "​Trigger and Action"​ Alert Setting}} {{tag>"​System Configuration"​ "​BioStar 2" "​Trigger and Action"​ Alert Setting}}
  
-====== How to configure Trigger and Action on Setting ====== +====== How to configure Trigger and Action on Setting ====== ​
-The trigger & action feature is used when you would like to send a custom output signal from a device or send an email to the administrator based on the occurrence of an alarm event. ​  +
-For instance, you can use this feature to trigger your alarm lamp when a forced door open alarm goes on. The system will simultaneously send an email to the administrator as well. \\ \\ +
-{{:​en:​2xtraining_trigger_action001.png?​nolink&​500|}} +
-\\+
  
-===== Available Triggers =====  +The trigger & action feature ​is used when you would like to send a custom output signal from a device or send an email to the administrator based on the occurrence of an alarm event. \\  ​
-Below is the full list of events that are available for triggers ​on the setting menu.\\ +
-Available events for Device: \\ +
-    *  Supervised Input (Open) +
-  *    Supervised Input (Short) +
-  *    Tamper On +
-  *    RS-485 disconnected +
-  *    Device restarted+
  
-<callout type="​primary"​ icon="​true">​  +For instance, you can use this feature to trigger your alarm lamp to go on simultaneously when forced door open alarm goes onThe system can also simultaneously send an email to the administrator as well\\ \\ 
-Supervised Input is used with DM20Please refer to [[en:​tc_appnote_dm20_wiring_examples]] for more information +
-</​callout>​+
  
-Available events for Door\\ +{{:en:2xtraining_trigger_action001.png?​nolink&​500|}} ​
-  * Held door open alarmedcan be used after setting to Door>​Alarm>​Held Open +
-  * Forced door open alarmed: can be used after setting to Door>​Alarm>​Forced Open +
-  * Held door opened: can be used after setting to Door>​Door Sensor +
-  * Forced door opened: can be used after setting to Door>​Door Sensor+
  
 +\\ 
 +
 +  ​
 +
 +===== Available Triggers =====  ​
 +
 +Below is the full list of events that are available for triggers on the setting menu. [Available on BioStar 2 Version 2.9.0 ]\\ 
 +
 +Available events for Device: \\ 
 +
 +    *  AC Power Failure  
 +
 +    *  Supervised Input (Open)  ​
 +
 +    *  Supervised Input (Short)  ​
 +
 +    *  Tamper on  
 +
 +    *  RS-485 disconnected  ​
 +
 +    *  RTSP disconnected  ​
 +
 +    *  RTSP connected  ​
 +
 +    *  Device restarted  ​
 +
 +    *  Device Disconnection Detected ​
 +
 +    *  1:1 authentication succeeded (ID + PIN) 
 +
 +    *  1:1 authentication succeeded (ID + Fingerprint) ​
 +
 +    *  1:1 authentication succeeded (ID + Fingerprint + PIN) 
 +
 +    *  1:1 authentication succeeded (ID + Face) 
 +
 +    *  1:1 authentication succeeded (ID + Face + PIN) 
 +
 +    *  1:1 authentication succeeded (Card)  ​
 +
 +    *  1:1 authentication succeeded (Card + PIN)  ​
 +
 +    *  1:1 authentication succeeded (Card + Fingerprint)  ​
 +
 +    *  1:1 authentication succeeded (Card + Fingerprint + PIN) 
 +
 +    *  1:1 authentication succeeded (Card + Face) 
 +
 +    *  1:1 authentication succeeded (Card + Face + PIN) 
 +
 +    *  1:1 authentication succeeded (Card + Face + Fingerprint)  ​
 +
 +    *  1:1 authentication succeeded (Card + Fingerprint + Face)  ​
 +
 +    *  1:1 authentication succeeded (ID + Face + Fingerprint)  ​
 +
 +    *  1:1 authentication succeeded (ID + Fingerprint + Face)  ​
 +
 +    *  1:1 authentication succeeded (Mobile Card)  ​
 +
 +    *  1:1 authentication succeeded (Mobile Card + PIN) 
 +
 +    *  1:1 authentication succeeded (Mobile Card + Fingerprint)  ​
 +
 +    *  1:1 authentication succeeded (Mobile Card + Fingerprint + PIN) 
 +
 +    *  1:1 authentication succeeded (Mobile Card + Face) 
 +
 +    *  1:1 authentication succeeded (Mobile Card + Face + PIN) 
 +
 +    *  1:1 authentication succeeded (Mobile Card + Face + Fingerprint) ​
 +
 +    *  1:1 authentication succeeded (Mobile Card + Fingerprint + Face) 
 +
 +    *  1:1 authentication failed (Mobile Card)  ​
 +
 +    *  1:1 duress authentication succeeded (Card + Fingerprint)  ​
 +
 +    *  1:1 duress authentication succeeded (Card + Fingerprint + PIN) 
 +
 +    *  1:1 duress authentication succeeded (Card + Face + Fingerprint)  ​
 +
 +    *  1:1 duress authentication succeeded (Card +Fingerprint + Face)  ​
 +
 +    *  1:1 duress authentication succeeded (ID + Face + Fingerprint)  ​
 +
 +    *  1:1 duress authentication succeeded (ID + Fingerprint + Face)  ​
 +
 +    *  1:1 duress authentication succeeded (Mobile Card + Fingerprint) ​
 +
 +    *  1:1 duress authentication succeeded (Mobile Card + Fingerprint + PIN)  ​
 +
 +    *  1:1 duress authentication succeeded (Mobile Card + Face + Fingerprint)  ​
 +
 +    *  1:1 authentication succeeded (Mobile Card + Fingerprint + Face)  ​
 +
 +    *  1: N authentication succeeded (Fingerprint) ​
 +
 +    *  1: N authentication succeeded (Fingerprint + PIN) 
 +
 +    *  1: N authentication succeeded (Face) ​
 +
 +    *  1: N authentication succeeded (Face + PIN) 
 +
 +    *  1: N authentication succeeded (Face + Fingerprint) ​
 +
 +    *  1: N authentication succeeded (Face + Fingerprint + PIN) 
 +
 +    *  1: N authentication succeeded (Fingerprint + Face) 
 +
 +    *  1: N authentication succeeded (Fingerprint + Face +PIN)  ​
 +
 +    *  1: N duress authentication succeeded (Fingerprint)  ​
 +
 +    *  1: N duress authentication succeeded (Fingerprint + PIN)  ​
 +
 +    *  1: N duress authentication succeeded (Face + Fingerprint)  ​
 +
 +    *  1: N duress authentication succeeded (Face + Fingerprint + PIN) 
 +
 +    *  1: N duress authentication succeeded (Fingerprint + Face)  ​
 +
 +    *  1: N duress authentication succeeded (Fingerprint + Face + PIN) 
 +
 +    *  Dual authentication succeeded ​
 +
 +    * Access denied (Invalid access group) ​
 +
 +    * Access denied (Disabled user) 
 +
 +    * Access denied (Invalid period) ​
 +
 +    * Access denied (Blacklist) ​
 +
 +    * Fake Fingerprint Detected  ​
 +
 +    * Access denied (Anti-tailgating) ​
 +
 +    * Access denied (Exceeded threshold temp.) ​
 +
 +    * Access denied (Temp. Not measured correctly) ​
 +
 +    * Access denied (Mask not detected)  ​
 +
 +    * Access granted (Check only) 
 +
 +    * Access granted (Soft temp violation on check only) 
 +
 +    * Access granted (Soft mask violation on check only) 
 +
 +    * Access granted (Soft temp and mask violation on check only)  ​
 +
 +    * Access denied (Exceeded threshold temp. On check only) 
 +
 +    * Access denied (Temp. Not measured correctly) ​
 +
 +    * Access denied (Mask not detected on check only)  ​
 +
 +    * Abnormal temp. detected (Exceeded threshold temp.)  ​
 +
 +    * Mask not detected ​
 +
 +     
 +
 +<callout type="​primary"​ icon="​true">  ​
 +
 +Supervised Input is used with a DM20. Please refer to [[en:​tc_appnote_dm20_wiring_examples]] for more information.  ​
 +
 +</​callout> ​
 +
 +  ​
 +
 +Available events for Door: \\ 
 +
 +  * Held door open alarmed: can be used after setting Door>​Alarm>​Held Open 
 +
 +  * Forced door open alarmed: can be used after setting Door>​Alarm>​Forced Open 
 +
 +  * Held door opened: can be used after setting Door>​Door Sensor ​
 +
 +  * Forced door opened: can be used after setting Door>​Door Sensor ​
  
-Available events for Zone: \\ 
-  * Scheduled lock zone alarm detected 
-  * Fire alarm zone alarm detected 
-  * Anti-passback zone alarm detected 
        
-===== Setting Up a Custom Signal Output =====  
-In the scenario below, we will send a custom signal from our A2 when there is a forced open event. \\ 
-1. Click **Setting > TRIGGER & ACTION**. ​ \\ 
-{{:​en:​2xtraining_trigger_action003.png?​nolink&​350|}} \\ \\ 
-2. Click **ADD TRIGGER & ACTION**. \\ 
-{{:​en:​2xtraining_trigger_action005.png?​nolink&​300|}} \\ \\ 
-3. Enter a name for this trigger on the **Name** textbox. ​ \\ 
-4. Click on the schedule drop box. Click **+ Add Schedule**. If you have a preconfigured schedule, you can use that one by selecting it. \\ 
-{{:​en:​2xtraining_trigger_action006.png?​nolink&​700|}} \\ \\ 
-5. Configure the schedule as necessary and click **Ok**. In this case, I would like the trigger to be on all day except for Sunday. ​ \\ 
-{{:​en:​2xtraining_trigger_action008.png?​nolink&​700|}} \\ \\  
-6. Now select the newly created schedule on the **Schedule** drop box. \\ 
-7. Select the **Door** radio button. \\ 
-8. Select the door this will affect. The A2 is installed on Door 3 in this example. \\ 
-9. Check **Forced door opened**. \\ 
-10. Select your device (A2).  \\ 
-11. Relay 0 is already used for the door lock so relay 1 will be used for the output. ​ \\ 
-{{:​en:​2xtraining_trigger_action010.png?​nolink|}} ​   \\ \\  
-12. Click on the **Signal** drop down box. \\ 
-13. Click **Add Signal**. \\ 
-14. Fill in the details as desired and click **Apply**. \\ 
-{{:​en:​2xtraining_trigger_action012.png?​nolink&​500|}} \\ \\  
-15.Click on the **Signal** drop box and select the signal you just created and click **Apply**. ​  \\ 
-16. Now when there is a forced door open event, the custom signal is sent to relay 1.  \\ 
-{{:​en:​2xtraining_trigger_action014.png?​nolink&​|}} \\ \\  
  
-===== Setting Up an Email Alert on BioStar =====  +Available events for Zone: \\  
-1. Click **Setting ​TRIGGER & ACTION**. \\ + 
-2. Click on your desired trigger. ​ \\  +  * Muster zone alarm detected  
-3. On Device / BioStar tab, click **BioStar** and check **BioStar**. \\ + 
-{{:​en:​2xtraining_trigger_action016.png?​nolink&​|}} \\ \\  +  * Occupancy Limit Violation (Count Full)  
-4. Click on the Gear icon on the action tab to setup your email. \\ + 
-{{:​en:​2xtraining_trigger_action018.png?​nolink&​|}} \\ \\  +  * Interlock door open denied alarm (Occupied)  
-5. Set up your SMTP. If you are not sure what the settings are, please ​ask your IT administrator. \\ + 
-{{:en:2xtraining_trigger_action020.png?​nolink&​400|}} \\ \\  +   * Interlock door open denied alarm  
-6. Add a **Recipient** and click **Apply**. \\ + 
-{{:en:2xtraining_trigger_action022.png?nolink&400|}} \\ \\  +  * Intrusion alarm detected  
-7. Now create a forced door open event. ​ \\ + 
-{{:​en:​2xtraining_trigger_action024.png?​nolink&​|}} \\ \\  +  * Occupancy Count Alert 2 Detected ​  
-8. The administrator will receive an alert email. \\ + 
-{{:en:2xtraining_trigger_action026.png?​nolink&​|}} \\ \\ +  * Occupancy Count Alert 1 Detected  
 + 
 +* Exit Occurred While Occupancy Count Zero   
 + 
 +  * Occupancy Availability Recovered ​  
 + 
 +  * Occupancy Full Detected  
 + 
 +* Scheduled lock zone alarm detected  
 + 
 +  * Fire alarm zone alarm detected  
 + 
 +  * Anti-passback zone alarm detected  
 + 
 +===== Setting Up a Custom Signal Output =====   
 + 
 +In the scenario below, we will send a custom signal from BioStation A2 Device when there is a forced opened trigger event. \\  
 + 
 +1. Click **Setting → TRIGGER & ACTION**. ​ \\  
 + 
 +{{:​en:​2xtraining_trigger_action003.png?​nolink&​350|}} \\ \\  
 + 
 +2. Click **ADD TRIGGER & ACTION**. \\  
 + 
 +{{:​en:​2xtraining_trigger_action005.png?​nolink&​300|}} \\ \\  
 + 
 +3. Enter a name for this trigger on the **Name** textbox. ​ \\  
 + 
 +4. Click on the schedule drop box. Click **+ Add Schedule**. If you have a pre-configured schedule, you can use that one by selecting it. \\  
 + 
 +{{:​en:​2xtraining_trigger_action006.png?​nolink&​700|}} \\ \\  
 + 
 +5. Configure the schedule as necessary and click **Ok**. In this case, I would like the trigger to be on all day except for Sunday. ​ \\  
 + 
 +{{:​en:​2xtraining_trigger_action008.png?​nolink&​700|}} \\ \\   
 + 
 +6. Now select the newly created schedule on the **Schedule** drop box. \\  
 + 
 +7. Select the **Door** radio button. \\  
 + 
 +8. Select the door this will affect. The BioStation A2 Device is installed on Door 3 in this example. \\  
 + 
 +9. Check **Forced door opened**. \\  
 + 
 +10. Select your device (BioStation A2).  \\  
 + 
 +11. Relay 0 is already used for the door lock so relay 1 will be used for the output. ​ \\  
 + 
 +{{:​en:​2xtraining_trigger_action010.png?​nolink|}} ​   \\ \\   
 + 
 +12. Click on the **Signal** drop down box. \\  
 + 
 +13. Click **Add Signal**. \\  
 + 
 +14. Fill in the details as desired and click **Apply**. \\  
 + 
 +{{:​en:​2xtraining_trigger_action012.png?​nolink&​500|}} \\ \\   
 + 
 +15.Click on the **Signal** drop box and select the signal you just created and click **Apply**. ​  \\  
 + 
 +16. Now when there is a forced door open event, the custom signal is sent to relay 1.  \\  
 + 
 +{{:​en:​2xtraining_trigger_action014.png?​nolink&​|}} \\ \\   
 + 
 +   
 + 
 +===== Setting Up an Email Alert on BioStar =====   
 + 
 +1. Click **Setting ​→ TRIGGER & ACTION**. \\  
 + 
 +2. Click on your desired trigger. ​ \\   
 + 
 +3. On Device / BioStar tab, click **BioStar** and check **BioStar**. \\  
 + 
 +{{:​en:​2xtraining_trigger_action016.png?​nolink&​|}} \\ \\   
 + 
 +4. Click on the Gear icon on the action tab to setup your email. \\  
 + 
 +{{:​en:​2xtraining_trigger_action018.png?​nolink&​|}} \\ \\   
 + 
 +5. Set up your SMTP. If you are unsure ​what the settings are, please ​follow this article → [[https://​support.supremainc.com/​en/​support/​solutions/​articles/​24000081661--biostar-2-how-to-configure-smtp-and-test-the-recipient-address|How to configure SMTP and Test the recipient address]]. \\  
 +{{:en:how_to_configure_trigger_action_smtp_section.jpg?​nolink&​400|}}\\ \\   
 + 
 +6. Add a **Recipient** and click **Apply**. \\  
 +{{:en:how_to_configure_trigger_action_received_email_section.jpg?noling&400|}} \\ \\   
 + 
 +7. Now create a forced door open event. ​ \\  
 + 
 +{{:​en:​2xtraining_trigger_action024.png?​nolink&​|}} \\ \\   
 + 
 +8. The administrator will receive an alert email. \\  
 + 