| Line 3: | Line 3: | ||
| 2022-05-10 | 2022-05-10 | ||
| \\ | \\ | ||
| - | <callout type="primary" icon="true"> | ||
| - | * After upgrading the firmware to v2.0.2, it is not able to downgrade to an earlier version (v1.x.x) firmware. | ||
| - | * When upgrading the firmware from v1.x.x to v2.x.x, it is recommended to use BioStar 2 or BioStar 2 Device SDK. | ||
| - | * When upgrading the firmware using a USB memory inevitably, first set **Menu Timeout** to **Always On** in the **Display & Sound** menu before proceeding with the upgrade. Also, even if a failure message is displayed during the upgrade, DO NOT remove the USB memory and wait until a success message is displayed. The device will restart automatically when the upgrade is complete. | ||
| - | </callout> | ||
| \\ | \\ | ||
| ==== New Features and Improvements ==== | ==== New Features and Improvements ==== | ||
| Line 21: | Line 16: | ||
| <text size="large">5.</text> Improved to check for the duplication of cards registered with users when transmitting user data from the server to devices. \\ | <text size="large">5.</text> Improved to check for the duplication of cards registered with users when transmitting user data from the server to devices. \\ | ||
| - | <text size="large">6.</text> Improved Arm/Disarm state to be written directly to the device's memory so that the state persists even if power is lost. \\ | + | <text size="large">6.</text> Improved the Arm/Disarm status is maintained if the device loses power. \\ |
| \\ | \\ | ||
| ==== Bug Fixes ==== | ==== Bug Fixes ==== | ||
| Line 34: | Line 29: | ||
| <text size="large">3.</text> The device restarted abnormally after scanning some cards on the device (Affects version: v1.0.0). \\ | <text size="large">3.</text> The device restarted abnormally after scanning some cards on the device (Affects version: v1.0.0). \\ | ||
| \\ | \\ | ||
| - | <text size="large">4.</text> If sending the Output Status Report Request command when the device was communicating with a 3rd party system via OSDP, the relay works, but the Output Status Report does not output (Affects version: v1.1.2). \\ | + | <text size="large">4.</text> When communicating with a 3rd party control panel via OSDP, the device does not respond to the Output Status Report command while the relay reacts to it (Affects version: v1.1.2). \\ |
| \\ | \\ | ||
| - | <text size="large">5.</text> When the device was communicating with a 3rd party system via OSDP, if the Input Status Request command was sent after the input port was grounded, the output was Inactive (Affects version: v1.1.2). \\ | + | <text size="large">5.</text> When communicating with a 3rd party control panel via OSDP, the device incorrectly responds as 'Inactive' when receiving the Input Status Request command while the input port is grounded (Affects version: v1.1.2). \\ |
| \\ | \\ | ||
| - | <text size="large">6.</text> When the device was communicating with a 3rd party system via OSDP, no data was output if sending the Device Capabilities command (FSF2-AB, FSF2-DB)(Affects version: v1.0.0). \\ | + | <text size="large">6.</text> When communicating with a 3rd party control panel via OSDP, the device does not respond to the Device Capabilities command (FSF2-DB, FSF2-AB)(Affects version: v1.0.0). \\ |
| \\ | \\ | ||
| <text size="large">7.</text> The master device restarted abnormally if changing the floor settings after setting up the scheduled unlock zone (Affects version: v1.0.0). \\ | <text size="large">7.</text> The master device restarted abnormally if changing the floor settings after setting up the scheduled unlock zone (Affects version: v1.0.0). \\ | ||
| Line 50: | Line 45: | ||
| <text size="large">11.</text> When authenticating with a duress fingerprint on a device with the auth mode set to ID+face+fingerprint/PIN, the duress fingerprint log does not leave (Affects version: v1.0.0). \\ | <text size="large">11.</text> When authenticating with a duress fingerprint on a device with the auth mode set to ID+face+fingerprint/PIN, the duress fingerprint log does not leave (Affects version: v1.0.0). \\ | ||
| \\ | \\ | ||
| - | <text size="large">12.</text> Device does not recognize some HID iCLASS Seos cards (Affects version: v1.0.0). \\ | + | <text size="large">12.</text> Device does not recognize certain HID iCLASS Seos cards (Affects version: v1.0.0). \\ |
| \\ | \\ | ||
| <text size="large">13.</text> Device does not connect to a 3rd party controller (Software House iSTAR Edge G2) via OSDP (Affects version: v1.0.0). \\ | <text size="large">13.</text> Device does not connect to a 3rd party controller (Software House iSTAR Edge G2) via OSDP (Affects version: v1.0.0). \\ | ||