Old revisions Add to book Export to PDF Fold/unfold all Book Creator Add this page to your book Book Creator Remove this page from your book Manage book (0 page(s)) Help System Configuration, BioStar 2, XPass D2 How to Configure XPass D2 XPass D2 is a new device introduced with BioStar 2.6. It is a dummy reader for reading cards, which means it doesn’t perform data matching on itself. The device can be used as a slave device, or a Wiegand reader to send Wiegand output. The device sends out a Wiegand signal with the default 26bit format and the Wiegand configuration will be done with a separate tool Device manager. Please refer to the article: How to use Suprema Device Manager App Adding as a Slave Device You will need a master device to add the slave D2 device. Refer to the article below to learn how to search for a slave device. RS485 Mode (Master, Default, Slave) Using the device as a Wiegand Reader If you already have used the device as a slave device before, you must reset the device to use it as a Wiegand reader (sending Wiegand output). 1. Delete the device(slave device) from BioStar 2 client. 2. Detach the metal bracket from the device. 3. Press the reset button. 4. Use the device as a Wiegand reader by adding it as a Wiegand Device on a master device. You cannot use the device as a slave device and use Wiegand output at the same time.